Heat & Glo LifeStyle RED60 2159-900 Indoor Fireplace User Manual


 
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 23
F. Installation Instructions and Venting In-
formation-PVI-DVP
These instructions are for appliances utilizing the PVI-DVP.
For appliances incorporating the PVK-80, see Section 7.J.
IMPORTANT: Failure to read and follow these instruc-
tions may create a possible hazard and will void the re-
place warranty.
CAUTION! Risk of Cuts or Abrasions. Wear protective
gloves and safety glasses during installation. Sheet metal
edges are sharp.
INTRODUCTION
The PVI-DVP is certied for use only on replaces manufac-
tured by Hearth & Home Technologies with IPI (intermittent
pilot ignition) gas controls.
The PVI operates on 120VAC, 60Hz electrical service which
is supplied at the replace junction box.
ComponentsandServicePartsList
ServicePartsList
Replacement parts can be obtained from your dealer. Re-
pair of the Power Vent should only be done by a qualied
service technician. A list of replacement parts is shown in
the service parts section of this manual.
INSTALLATIONOFPVI-DVP
1.INSTALLATIONPRECAUTIONS
a. This device must be installed by a qualied installer in
accordance with these instructions.
b. Safety inspection of the venting system should be
performed before and after installation of this power
vent. Consult local code ofcials and follow applicable
installation codes.
c. DONOTINSTALLDAMAGEDEQUIPMENTORVENT
COMPONENTS.
d. The exit termination of mechanical draft systems shall
not be less than seven feet above grade when located
adjacent to public walkways and at least ten feet from
lot line or adjacent buildings.
e. A mechanical drafting venting system shall terminate at
least three feet above any forced air inlet located within
ten feet.
f. Disconnect electrical power supply before making wiring
connections.
g. Venting of more than one appliance in a common vent
system is prohibited.
2.INSTALLATIONGUIDELINES
WARNING: RISK OF FIRE AND BURNS. DO NOT in-
stall PVI with the access panel facing upward. Over-
heating may occur.
a. If the PVI-DVP is being installed in a conned space
(such as a utility closet, mechanical room or attic space)
with a total volume less than 720 cubic ft, an 8 inch by 16
inch hole will be required directly in front of the access
panel. The conned space where PVI is installed, and
the space to which the access hole opens, must add up
to at least 720 cubic feet. This hole may be covered with
a decorative cover as long as the cover has a minimum of
50% open air. This also applies to a replace chase.
If the PVI-DVP is being installed in a space greater than
720 cubic ft the 8 inch by 16 inch access hole is still
required, but a solid cover may be used.
The decorative cover CANNOT be located on an outside
wall that is open to the environment.
b. For installations near loose-ll insulation (such as attics)
a minimum clearance of six inches must be maintained
between the access panel and the insulation.
c. The access panel opening must be located such that
access for service and adjustment is available. The
NEC requires a minimum of 30 inches of space around
the opening and 36 inches in front of the opening to
the access panel. Consult ofcials having jurisdiction
regarding regional requirements.
h. Clearances between the vent pipe and combustible ma-
terials must be maintained at 3-inch top, 1-inch sides,
and 1/2 inch bottom.
i. All outer pipe joints must be sealed with high tempera-
ture silicone. See Section10.A.
CAUTION: Failure to install, operate, and maintain the
power venting system in accordance with manufacturer's
instructions will result in conditions which may produce
bodily injury and/or property damage.
NOTICE: The blower motors present in this appliance
will generate sound during operation. The effects of the
increased sound level can be minimized with careful
planning during installation of the system. Locating the
powervent service access grill in an area remote of
immediate living space will reduce the effects of the added
sound generated during operation.