NOTE: Maximum total vent run= Total vertical vent run + Total horizontal vent run
V1
H1
H2
H3
V2
MAXIMUM
VERTICAL
DROP
DIRECTVENTWITH2FT.MINIMUMVERTICALOFFTOPOFAPPLIANCE
MAX.ELBOWS
(45°&90°)
MAX.TOTALVENTRUN
TotalV+TotalH(FT.)
MAX.VERT.DROP
V
2
(FT.)
3 26ft. 7ft.
4 16ft. 7ft.
5 16ft. 7ft.
1ft.verticaldropdecreaseshorizontallengthby2ft.
Note: 1 ft. of vertical drop decreases
horizontal length by 2 ft.
Figure7.28PowerVentPositionedBeforeVerticalDrop
DIRECTVENTWITH3FT.MINIMUMVERTICALOFFTOPOFAPPLIANCE
MAX.ELBOWS
(45°&90°)
MAX.TOTALVENTRUN
TotalV+TotalH(FT.)
MAX.VERT.DROP
V
2
(FT.)
3 30ft. 7ft.
4 22ft. 7ft.
5 22ft. 7ft.
1ft.verticaldropdecreaseshorizontallengthby2ft.
DIRECTVENTWITH4FT.MINIMUMVERTICALOFFTOPOFAPPLIANCE
MAX.ELBOWS
(45°&90°)
MAX.TOTALVENTRUN
TotalV+TotalH(FT.)
MAX.VERT.DROP
V
2
(FT.)
3 45ft. 7ft.
4 38ft. 7ft.
5 30ft. 7ft.
6 22ft. 7ft.
1ft.verticaldropdecreaseshorizontallengthby2ft.