Heat & Glo LifeStyle RED60 2159-900 Indoor Fireplace User Manual


 
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 41
Figure7.37.RED60PVK-80WiringDiagramwithIntelliFirePlusPilotIgnition
FAN
INTERMITTENT
PILOT IGNITOR
ORANGE
WHITE
SENSOR
WIRE
IGNITER
WIRE
6VDC TRANSFORMER
ELECTRICAL
ACCESS KNOCKOUT
APPLIANCE ON/OFF CONTROL
HARNESS
THERMO SNAP DISC
HARNESS
JUMPER
HARNESS
AUX300
MODULE
WALL SWITCH
JUMPER WIRE
IPI WIRE
HARNESS
MALE/FEMALE
WIRE ASSEMBLY
8K1-PVI
ORANGE
GREEN
GREEN
VALVE
JUMPER
JUMPER
JUMPER
HI LIMIT SWITCHES
GROUND TO
FIREPLACE
CHASSIS
JUNCTION BOX
TO FAN OUTLET
ON JUNCTION
BOX
PVK-80 POWER VENT
(WIRES MAY NEED TO BE SPLICED
TO REACH APPLIANCE)
(BLACK)
(GREEN)
(WHITE)
(WHITE)
(BLACK)
(GREEN)
(RED)
(BROWN)
WIRE HARNESS
(SHIPPED IN ACCESSORY BOX)
(RED)
(BROWN)
WIRE HARNESS
(SHIPPED IN
ACCESSORY BOX)
(RED)
(BROWN)
CONTROL LEVER -
REMOVE SCREW
TO ADJUST
SECURE CONTROL
LEVER WITH SCREW
AFTER ADJUSTMENT
Figure7.38