4-30 SECTION 4: MASTER FILE ENTRY
PIN Timeout. Optional. The maximum amount of time, in seconds, which can pass between
the presentation of a key and the entry of a verification PIN. Default is 10.
Max Inv. PINs. Optional. The maximum number of invalid PIN entry attempts to permit
before cancelling the key presentation. Default is 4.
VIPs Digits. Optional. The number of digits in the PIN number for doors using keypads only.
The range is 4 to 8. Default is 4.
Modem Definition. Not used when the SE 6000 is connected directly or in a dial-up
configuration.
Latched Contact. Optional. The number of the output contacts that are assigned as a
latched contact (0—51). Default is 0.
ABA Site Code Grp. Optional. The ABA site code group ID number.
EMPI Alt1 Code. Optional. Alternate EMPI site code #1.
PIN seed. Optional. The base seed number used when generating PINs. The value entered
here has priority over the default PIN seed value entered on the [pndfentr] screen (see
Entering Default PIN Digits and Seed for an SE 422 in this section). Default is 0.
PIN Digits. The number of digits in the PIN code for this SE 422. The value entered here
has priority over the default PIN digits value entered on the [pndfentr] screen (see Entering
Default PIN Digits and Seed for an SE 422 in this section). Default is 0.
EMPI Alt2 Code. Optional. Alternate EMPI site code #2.
# of Retry Times. Used to inform a remotely connected SE 422 the number of times to
attempt to contact the host computer over telephone lines before considering a connection
to be currently impossible to make.
XON/XOFF. Terminal Port and Host Port: Used to inform the SE 422 whether XON/XOFF
flow control will be used at either of these two ports. Used for remotely connected SE 422s
only.
Bldg Mode Indicators. Conditional. Enter the input point contact number or output relay
number to initiate and display the status of the building mode.
Monitor — Input point contact ID (0 — 75)