2-10 SECTION 2: MONITOR SECURITY ACTIVITY
F5 PRNT ON. Switch printer #1 on or off depending on current state (used to control log printer
only).
F6 PRNT ON. Switch printer #2 on or off depending on current state.
Forgive Passback
A passback violation occurs when a keyholder uses their key to reenter a door without first using
their key to exit the same door. For example, a keyholder (number 1) uses their key and unlocks
the door. The system flags keyholder number 1 as "in." Keyholder number 1 passes their key to
keyholder number 2. When keyholder number 2 attempts to use the key, the systems gives
keyholder number 1 a passback violation. This was originally developed for parking lot control.
The system handles vehicle and personal passback separately.
To allow the keyholder to enter the area, use the forgive passback function.
1. Enter key number (or ALL for all keyholders); press Enter.
2. Press F1 to confirm the passback forgive.
Manual Access Granted
Used when a command key is not available (mislaid, stolen, etc.), this function allows the operator
to grant manual access following entry of the key number (system records entry). Enter the key
number and reader ID. Enter the keyholder ID if the key number is unknown. Manual access is
available for all keyholders at any reader regardless of access assignments.
Force Table Download
This function first writes database information to a text file, then transfers the information to host
memory and LC memory (if applicable). The function is used during system servicing, and when
requested by customer support. A sample screen follows: