Ricoh GLD0-0025-01 Window User Manual


 
AIOxxx574W The data stream converter ignored
page-oriented keywords in the DJDE
packet on record number due to a prior
page oriented DJDE on this page.
Explanation: The data stream converter found more
than one DJDE packet that contained page-oriented
DJDEs on a page. You can only apply one
page-oriented DJDE to each page. The converter
ignores all packets after the first packet.
System action: InfoPrint XT might not continue to
process the job.
User response: Correct the original Xerox job so that it
uses the syntax rules for page-oriented DJDEs, and
reconvert the job.
AIOxxx575W The data stream converter found a
GRAPHIC= DJDE with no options and
no preceding IMAGE= DJDE that used
option T. The converter discarded the
GRAPHIC data for image image_name.
Explanation: The GRAPHIC DJDE can
document-interleave because it has no parameters other
than the image name. However, two inconsistencies
exist. First, document-interleaved GRAPHIC DJDEs
must occur at the beginning of the job, but InfoPrint XT
found this GRAPHIC DJDE after text data. This is
where page-interleaved graphics occur. Second, a
preceding IMAGE DJDE must reference a
page-interleaved GRAPHIC DJDE. InfoPrint XT found
no prior matching IMAGE DJDE.
System action: InfoPrint XT continues processing the
job, but the output is not correct.
User response: Correct the application that created the
data stream so that all document-interleaved
GRAPHICs occur at the beginning of the job, and all
page-interleaved GRAPHICS are referenced by a
preceding IMAGE DJDE.
AIOxxx576E The number of inline graphics exceeded
the maximum of 1,000,000. Inline
graphics will overlay existing images.
Explanation: InfoPrint XT tracks page segments that
correspond to inline graphics using the naming
convention SGnnnnnn. nnnnnn is a number from 0
through 999999. If more inline graphics are found than
can be tracked using this convention (after SG999999
has been used), InfoPrint XT begins using previous
names, starting with SG000000. InfoPrint XT replaces
the page segments associated with the reused names.
System action: InfoPrint XT continues processing the
job, but the output is not correct.
User response: Reduce the number of inline graphics,
or split the job into smaller jobs.
AIOxxx582E FILE - The data stream converter does
not support inline files in the 80-byte
card image format (file input format
parameter C) and may print their
contents as unusable data. The converter
only supports the LPS format (file input
format parameter L).
Explanation: The data stream converter found one or
more FILE DJDEs that specify the card image format
instead of the required LPS format.
System action: The data stream converter ignores the
card-image inline Xerox file or files that follow the FILE
DJDE.
User response: Regenerate the FILE DJDE job so that
all inline resources are in the LPS format, and that all
FILE DJDEs specify a file input format parameter of L.
Then, rerun the job.
AIOxxx589E The data stream converter found
incorrect font enlargement factors *
enl_vert * enl_horiz on record
record_number and substituted factors * 1
* 1. Valid factors are 1, 2, 4, 8 or 16.
Explanation: The Xerox LPS does not support DBCS
font enlargement factors other than 1, 2, 4, 8, or 16.
System action: InfoPrint XT ignores the specified
enlargement factor.
User response: Correct the font enlargement factor.
Then, submit the job and convert it again.
AIOxxx590E The data stream converter could not
find image image_name in the
reformatted Xerox resource path.
Explanation: While processing a Xerox data stream,
InfoPrint XT determined that the data stream
referenced a Xerox IMG, image_name, which is not
loaded on the system.
System action: InfoPrint XT continues to process the
job, but the AFP output that it produces is not correct.
User response: Load the resource identified in the
message and resubmit the job.
AIOxxx591I FEED - The data stream converter will
interpret FEED=tray_name as
FEED=MAIN.
Explanation: While xclb=none was in effect, the data
stream converter found a FEED DJDE that specified
tray_name, which is a name other than MAIN, AUX, or
OPR. The converter interprets the FEED DJDE as
FEED=MAIN, and generates AFP that invokes input
media source 1.
System action: InfoPrint XT continues to process the
job.
Appendix D. Resource utility messages and data stream converter messages: AIOxxxnnnx 139
| |
|
|
|
|
|
|
|
|
|
|