Ricoh GLD0-0025-01 Window User Manual


 
the COLLATE DJDE in the input file and reconvert the
job.
AIOxxx563W The data stream converter ignored an
incorrect COLLATE change request.
Explanation: The COLLATE DJDE that InfoPrint XT
found is not valid after the first data record of the
report.
System action: InfoPrint XT continues processing the
job.
User response: Make sure of the correct placement of
the COLLATE DJDE in the input file and reconvert the
job.
AIOxxx564E djde_name - DJDE value value is not valid
for the specified conversion units.
Explanation: InfoPrint XT cannot process the value
value correctly. For units such as IN (inches) or CM
(centimeters), InfoPrint XT expects no more than three
decimal places. For DOTS, InfoPrint XT expects an
integer value.
System action: InfoPrint XT continues processing the
job, but the output might not be correct.
User response: Round any decimal values to three
decimal places, or supply integer values for DOTS.
AIOxxx565E djde_name - DJDE value input is not valid
for a numeric entry field.
Explanation: InfoPrint XT cannot process the value
input correctly. InfoPrint XT does not process the DJDE
(djde_name). DJDE naming conventions require a
numeric entry with specific rounding values.
System action: InfoPrint XT continues processing the
job, but the output might not be correct.
User response: Correct the value and reconvert the
job.
AIOxxx566E DJDE_keyword DJDE option_name is
not valid.
Explanation: The option_name option of the
DJDE_keyword DJDE is not valid.
System action: InfoPrint XT ignores the DJDE
keyword and continues processing.
User response: Correct the DJDE and reconvert the
job.
AIOxxx567E The data stream converter found an
incorrect copy sensitive change request.
Explanation: A copy-sensitive MODIFY, FORMS, or
BFORM change request was made during the
processing of the current report. You can only specify
copy-sensitive MODIFY, FORMS, and BFORM
commands at the beginning of a report. The program
ignores the request. After text has printed on a
copy-sensitive report, you can only change a MODIFY,
FORMS, or BFORM command to NONE.
System action: InfoPrint XT continues processing the
job, but the output might not be correct.
User response: Correct the request that was made
after the beginning of the report and reconvert the job.
AIOxxx568E The data stream converter could not
find graphic image resource_name in the
image correlation table and did not
process the command DJDE command.
Explanation: The named resource, resource_name, was
not found. The resource name might be misspelled. The
resource might not be loaded on the InfoPrint XT
server or it might have been loaded as a resource that
belongs to a specific resource group.
System action: InfoPrint XT continues processing the
job, but the output might not be correct.
User response: Check the spelling of the resource
name. Make sure that the resource has been loaded
either as a shared resource or as a resource that belongs
to a specific resource group. Then, reconvert the job.
AIOxxx569E The data stream converter found
incorrect DJDE command command.
Explanation: The listed command (command) is not a
known DJDE command, or its specification or format is
not correct. The program might not process the input.
System action: InfoPrint XT might not continue to
process the job.
User response: Correct the command and reconvert
the job. For SHIFT or XSHIFT DJDEs that are not valid,
the previous front or back side SHIFT or XSHIFT value
might remain in effect. The DJDE report provides
details.
AIOxxx573W Graphic image image_name is not active.
The data stream converter did not
process the command command.
Explanation: The data stream converter did not find
graphic image image_name before it found the ALTER
or CANCEL command for the image.
System action: InfoPrint XT might not continue to
process the job.
User response: Correct the original Xerox job so that it
uses the syntax rules for graphic images. Then,
reconvert the job.
138 InfoPrint XT Guide
|
|
|
|
|
|
|
|
|
|
|