AIOxxx293I The data stream converter needs Xerox
resource resource_name for this
conversion.
Explanation: InfoPrint XT did not find a required
Xerox resource during job conversion.
System action: InfoPrint XT cannot complete the
conversion.
User response: Make sure that you load the resource
on the system, and that you rerun the job. You might
also receive this as an informational message when you
scan jobs for required resources.
AIOxxx294W A record in file_name was longer than
the maximum record length of nn. The
transform ignored data in bytes beyond
the expected length.
Explanation: A logic error occurred while reading
from file file_name.
System action: InfoPrint XT cannot process the
request.
User response: Examine the file and make sure that it
is not corrupt. Make sure that the xcc conversion
parameter specifies the correct type of carriage control,
and that the data stream conversion parameters are
correct. Then, do the operation that caused this error
again.
AIOxxx298U A program or operating system error has
occurred. Internal diagnostic
information follows:
error_info error_info
Explanation: A logic error occurred. InfoPrint XT
supplies a phase name, diagnostic information, or both,
to help identify the problem.
System action: The process fails.
User response: Report this message to your technical
support representative.
AIOxxx400I Data stream converter processing
aborted due to unrecoverable errors.
Explanation: This message occurs when the
conversion process ends abnormally. Previous messages
give the reason for abnormal end of the process.
AIOxxx404I The data stream converter will process
the input file by using cc_type carriage
control characters.
Explanation: InfoPrint XT examined the job data to
determine whether ANSI or IBM3211 control characters
were in use. The type of controls found was different
from the type expected. control_type is either:
v ISO/ANSI/FIPS
v IBM3211 (machine code)
System
action: InfoPrint XT continues converting the
job.
User response: Check the printed output. If the output
is not correct, specify the correct type of carriage
control for the job. Use the xcc conversion parameter.
Then, convert the job again.
AIOxxx407I Reading online / offline JDL query
parameters.
Explanation: This is an informational message that
indicates that InfoPrint XT has begun to read the
online/offline JDL query parameters to determine
whether the job is an online or offline job. It requires
no user response.
AIOxxx408I Reading reformatted Xerox resource
dump parameters.
Explanation: This is an informational message that
indicates that InfoPrint XT has begun to read the
reformatted Xerox resource dump parameters. It
requires no user response.
AIOxxx420S UNDEFINEDFILE condition raised on
name, ONCODE number. Check name
path or file.
Explanation: InfoPrint XT did not find the input file
for the job, or it detected incorrect or conflicting
attributes for the file.
System action: The process fails.
User response: If you are submitting a job from disk,
check both the path to the file and the spelling of the
file name to make sure that the path and file exist. If
you are manually converting the job with the
pdxtx2afp command, also make sure that the xrecfm
parameter value correctly matches the fixed or variable
record format of the input data, and that the xlrecl
parameter value is in the valid range for the record
format. If the problem continues after you have verified
the path name, file name, file attributes, and parameter
values, report this message to your technical support
representative.
AIOxxx421S RECORD condition raised on file_name,
ONCODE nn. Check file_name file
attributes.
Explanation: The named file (file_name) has an
incorrect record format (xrecfm=) or record length
(xlrecl=) specified by the conversion parameters for the
job.
System action: InfoPrint XT produces no output, or
produces incomplete output.
134 InfoPrint XT Guide
|
|