STP-H600/H1000 Series Instruction Manual
16.2 16.2 Specifications for the STP Control Unit
Table 16.2 Specifications for the STP Control Unit
Item Specifications
Input voltage V AC
200 to 240 10%
At start: kVA 2.6
Input power
Under rated operation: kVA 1.0 to 2.6
Input frequency Hz
50/60 2
Input phase Single phase
Rated current of main breaker A 20
Motor drive system 3-phase transistor-inverter
Output voltage under rated
operation(3-phase)
V AC
52
Output frequency under rated
operation
Hz
584
Ambient temperature range
0 to 40
Storage temperature range
- 25 to + 55 (excluding a battery)
Battery storage temperature range
- 20 to + 40
Mass
*1
kg 40
Battery used 12 V 2Ah x 4 (Japan Storage Battery Co.,
Ltd./Small-Sized Sealed Lead-Acid
Battery/PORTALAC series PE12V2WS)
Operation switches [Front Panel]
· POWER ON/OFF
(Illuminated alternate push button
switch, black/green)
· MOTOR START
(Momentary push button switch, black)
· MOTOR STOP
(Momentary push button switch, red)
· HEATING ON/OFF
(Illuminated alternate push button
switch, black/green)
[Rear Panel]
· MANUAL/REMOTE Changeover
(Toggle switch)
Panel indication lamps
· ACCELERATION (Green LED)
· NORMAL OPERATION (Green LED)
· BRAKE (Yellow LED)
· EMERGENCY OPERATION (Red LED)
· FAILURE (Red LED)
· OVER TEMPERATURE (Red LED)
· BATTERY OPERATION (Red LED)
· [Switch built-in Lamps]
· POWER ON (POWER ON/OFF, green)
· HEATING ON (HEATING ON/OFF,
green)
16-2
*1
: Mass is a value of state that the only standard accessory was installed. (except the optional accessory)