Mitsubishi Electronics QJ71DN91 Water System User Manual


 
3 - 41 3 - 41
MELSEC-Q
3 SPECIFICATIONS
(15) Master Function For IO Address Area (addresses 0500
H
to
05FB
H
/1280 to 1531)
The head addresses and sizes (in word module) of the "input data for the master
function" area and the "output data for the master function" area, which are used
by each slave node, are stored.
This area can be used to check the head address of each node.
0500
H
0501
H
0502
H
0503
H
0504
H
5FB
H
Input data head address of
the 1st slave node
Input data size (word count) of
the 1st slave node
Output data head address of
the 1st slave node
Output data size (word count) of
the 1st slave node
Input data head address of
the 2nd slave node
Output data size (word count) of
the 63rd slave node
(16) Present Link Scan Time (address 05FC
H
/1532)
The current link scan time (module: ms) is stored.
(17) Minimum Link Scan Time (address 05FD
H
/1533)
The minimum link scan time after the power in turned ON (module: ms) is stored.
(18) Maximum Link Scan Time (address 05FE
H
/1534)
The maximum link scan time after the power in turned ON (module: ms) is
stored.