Guardian Technologies N7001V2 Smoke Alarm User Manual


 
Ð 98 Ð
Note: If the operator makes a mistake in entering the proper 4-digit ID code,
the operator just needs to re-enter the correct code. If after 5 minutes have
elapsed without the central station callback, only a new alarm will initiate a new
2-way voice session.
Operator Commands The following table summarizes the central station operator commands available.
To perform a command, the operator simply presses the appropriate telephone
key(s).
OPERATOR COMMANDS
Key Function Comments
1 Talk Mode Operator can speak to persons on
(1 beep) premises.
2 VOX Mode (2-way voice) Operator can both speak and listen
(2 beeps) to persons on premises.
3 Listen Mode Operator can listen to activity at the
(3 beeps) premises. Repeated depressions of
"3" toggle keypad listening levels from
high to medium to low to high, etc.
4 Select Next Keypad The first keypad is keypad #1.
5 Select Keypad #2
6 Select Keypad #3
7 Extend timeout 90 secs This allows more time for the operator
to begin a session.
88 Disconnect with callback The operator can choose to discon-
nect the session, but call back within 5
minutes.
99 Disconnect This command terminates a session.
0 Return to Listen to All Mode
*8nn Select Keypad nn Use this command to select any
(keypad No. 01-15) keypad. e.g. *803 selects keypad #3.
# Reset and select Keypad #1 Returns session to Listen Mode
EVENT LOGGING
Event Logging Procedures
IMPORTANT: In order for time and date stamping to occur, the
system's real-time clock must be set. Refer to the SETTING THE
REAL TIME CLOCK section.
The system has the ability to record various events in a history log (100 event
capacity) wherein each event is recorded in one of five categories (alarm, check,
bypass, open & system), with the time and date of its occurrence (if real-time clock
is set). The log may be viewed (Display Mode) using an alpha keypad.
NOTE: The VISTA-40 does not support event log printing.
EVENT LOG MODE COMMANDS
Display Mode (installer or master): Enter CODE + [#] + [6] + [0]
Clear Event Log (installer only): Enter CODE + [#] + [6] + [2]
To EXIT Event Log Mode: Press [*] at any time.
Programming The system can be configured for the following event log activities:
¥ Specific categories of events can be selectively enabled (field 1*70).
¥ The time stamp can be set for either 12 or 24 hour formats (field 1*71).
¥ Set event log time/date report enable (fields 1*40 & 1*41).
Event Logging Display After entering event log mode, the following will be displayed:
ENTER 0 = RECENT
1 = COMPLETE
The Event Log holds up to 100 events, and can display
all events in a category (complete), or only those events
in a category occurring since the last Clear Event Log
command (recent). Note that once the Event Log is full,
the oldest event will be erased upon logging of any new
event. Press the desired display mode key, 0 or 1.