Dialer Options (continued)
* 80 Zone Type
Restores
For Types 9-10
Enter 1 to enable restore reporting for individual zone types. Enter 0 if no
restore report is desired for a zone type.
*81-*82 Non-Alarm
Report Codes
Enter the appropriate report codes as indicated on the programming form.
*89 Restore
Report Timing
Enter 0 for instant restore report, as zone restores. Enter 1 for reporting after bell
timeout if zone restored. Enter 2 for restore report when system is subsequently
disarmed
2ND PAGE FIELDS
1*33 Touch-Tone
W/Rotary Backup
Enter 1 to enable Rotary back-up dialing if communicator was not successful on
dialing using touch-tone DTMF on first attempt. Enter 0 if this option is not be to
be used.
1*34 Comm. Split
Report Selection
This field allows certain reports to be directed to either the primary or secondary
phone number. Enter 0, 1, or 2, in accordance with the following: 0 = split
reporting disabled; 1 = alarm, alarm restore & cancel reports sent to primary Telco
number, all others to secondary Telco number; 2 = open/close & test reports
sent to secondary Telco number and all other reports to primary. See *51 for
split/dual reporting comments.
1*40-1*41 Arm Stay
ÊÊ& Time Set Report
ÊÊCodes
Enter the appropriate code as shown on the programming form.
Wireless Options
1*28 RF TX Low
Battery Sound
Enter 0 if audible beep and display annunciation upon RF transmitter low battery
condition is desired only in disarmed state. Enter 1 if audible beep and display is
desired in both armed and disarmed states. Must be 1 for UL.
1*29 RF TX Low
Battery Report
Enable
Enter 1 if a trouble message for RF transmitter low battery conditions is to be sent
to the central station. Enter 0 if no report for transmitter low battery is desired.
Note that a trouble message will be sent for a transmitter supervision failure
independent of this selection. Must be 1 for UL.
1*30 RF Rcvr
Supervision
Check-In Interval
Enter the check-in monitoring interval in 2-hour increments. Enter 02-15 times 2
hours (4-30 hours). Failure of a receiver to receive any RF signal within the time
entered will result in activation of the response type programmed for zone 90 for
the first receiver and zone 88 for the second receiver and their related
communication reports. Enter 00 to disable receiver supervision. Max. "6" (12 hr)
for UL.
1*31 RF Transmitter
Check-In Interval
Enter the check-in monitoring interval in 2-hour increments; enter 02-15 times 2
hours (4-30 hours). Failure of an individual transmitter to send a supervision signal
within the time entered will result in a trouble response and related
communication report. Entry 00 disables transmitter supervision. Max. "6" (12 hr)
for UL.
1*32 Receiver Type Enter 1 if using 4281 series receivers. enter 2 if using 5881 series receivers.
0 = none.
1*44 Wireless Keypad
Tamper Detect
Enter 1 to enable tamper detection on wireless keypad. Enter 0 if tamper
detection is not desired. If this feature is enabled, any attempt to tamper by
means of many trial entries at a wireless keypad will be blocked by the control
panel. If more than 40 key depressions are received without a valid sequence
(arm, disarm, etc.), the Control panel will disable the wireless keypad. The inhibit is
removed once a valid key sequence is received from a wired keypad.
1*48 Wireless Keypad
Assignment
Enter the partition in which the RF keypad is used, 1-2. Enter 0 if no RF keypad
is used.
1*49 Suppress TX
Supervision
Sound
Enter 1 to disable trouble sounding for transmitter check-in failure. Enter 0 if
audible trouble sounding is desired. Must be "0" for UL.