Guardian Technologies N7001V2 Smoke Alarm User Manual


 
Ð 27 Ð
Compatible 5800 Series
Wireless Devices
(Refer to the installation
instructions provided with
each transmitter)
5801................... 4-Button Transmitter
5802................... Pendant Panic Transmitter
5802CP.............. Belt Clip Panic Transmitter
5802MN.............. Belt Clip or Pendant Panic Transmitter
5804................... 4-Button transmitter
5806................... Photoelectric Smoke Detector
5807................... Photoelectric Smoke Detector
5808................... Photoelectric Smoke Detector
5816................... Miniature Transmitter
5816MN.............. Miniature Transmitter
5816TEMP ......... Low Temperature Transmitter
5817................... 3-Point Transmitter
5818................... Recessed Transmitter
5827................... Wireless Keypad
5849................... Glass Break Detector
5890................... Dual Element PIR
VOLTAGE TRIGGERS (Connector J7)
(Ground S t art Module, Ke y swit ch, R e mot e Ke y pad Sounde r, or a non-A de mco A A V Unit
requiring a Voltage trigger)
General Information Connector J7, located on the right hand side of the main PCB provides 4 latching
trigger outputs for operating the 675 Ground Start Module, the 4146 Keyswitch,,
a non-Ademco AAV unit, a remote keypad sounding piezo, and for triggering
auxiliary alarm signaling equipment (such as the 7720 and 7920SE LORRA
Subscriber Radios). Note that these output triggers can be enabled by partition
via programming field 2*20.
The pin assignments of this connector are shown below. Use only the 4142TR
9-wire cable (available as an option) for making connections to this connector.
1 2 3 4 5 6 7 8 9
GRAY
YELLOW
WHITE
RED
GREEN
BROWN
BLUE
BLACK
GROUND
OUT 1
GROUND
OUT 2
GROUND
OUT 3
GROUND
OUT 4
J7 CONNECTOR
OUT 1: GROUND START OR OPEN/CLOSE
OUT 2: FIRE OR KEYSWITCH ARMED LED
OUT 3: BURGLARY/AUDIBLE PANIC/AUXILIARY
OUT 4: SILENT PANIC/DURESS OR KEYSWITCH READY LED
N/U
4142TR CABLE
J7 CONNECTOR
FOR VOLTAGE
TRIGGERS
Output 1: Operates, by default, as a trigger for the 675 ground start module. This output
may optionally be programmed via field 1*46 to operate as an open/close trigger,
a remote keypad sounder output , or a trigger for an AAV unit from another
manufacturer, as follows:
1*46 0 = ground start module
1 = open/close trigger
2 = remote keypad sounding
3 = AAV trigger (non-Ademco AAV unit only!)
Only one of these options may be used at any time.
Rating: When Activated: 10Ð13.8 VDC through 4K
ohms (2.5mA max).
When De-activated: 100 ohms to ground.