Guardian Technologies N7001V2 Smoke Alarm User Manual


 
Ð 54 Ð
Partition-Specific Field Descriptions (continued)
*29 Quick Arm Enter 1 to enable arming of the burglary system in AWAY, STAY, INSTANT or
MAXIMUM modes by using the # key instead of the security code. When armed,
reports closing as User 0 if open/close reporting for User #2 (typically a master
level user) was enabled for a given partition. If quick arm is used, the installer code
and authority level 5 code cannot disarm the system. Enter 0 if Quick Arm is not
desired. In either case, the security code must always be used to disarm the
system.
* 32 Primary
Subscriber Acct #
Enter a 3 or 4 digit (depending on report format) primary subscriber account
number 00-09; B-F (11-15). Each number requires a 2-digit entry so as to allow
entry of hexadecimal digits (B-F). If a 3 digit account number is to be used, only
enter data in the first 3 locations, leaving the last one unfilled, by entering a *.
* 3 8 Prevent Zone XX
Bypass
Entering a zone number (01-64) prevents that zone from being bypassed by the
user. Enter 00 if this feature is not desired (all zones can be bypassed). This does
not affect fire zones, which the system prevents from being bypassed.
*39 Open/Close Report
For Installer Code
Enter 1 if open/close reporting for the installer is desired. Otherwise enter 0
(disable).
*84 Swinger
Suppression
This option limits the number of messages (Alarms or Troubles) sent for a specific
channel in an armed period (Swinger Suppression). Enter 01-15. If 00 is
selected, all Alarm or Trouble codes are reported. Must be 00 (disabled) for UL.
* 8 5 Enable Dialer
For Panics &
Duress
Enter 1 for each panic/duress for which reporting is desired. Otherwise enter 0
(disable).
* 8 7 Entry Warning Enter 0 for 3 short beeps, or 1 for slow beeps that continue for the entire entry
delay period.
* 8 8 Burg. Alarm
Comm. Delay
Enter 0 for no delay on burglary alarm communication, or 1 for 16-second delay
(no delay on 24-hour reports).
*90 Secondary
Subscriber Acct #
Enter the 3 or 4 digit number (depending on report format) for the secondary
subscriber account, 00-09; B-F (11-15). Each number requires a 2-digit entry so
as to allow entry of hexadecimal digits (B-F). If a 3-digit number is to be used, only
enter data in the first 6 locations, leaving the last two unfilled. Default=15 15 15
15. Erase the field by entering *90*. NOTE: This field
must
be programmed if a
secondary phone number is used (field *34). This account number can be the
same as the primary account number.
2nd Page Fields
1*43 Permanent
Keypad
Backlighting
Enter 1 if it is desired that backlighting for the keypad display remain on at all times.
Enter 0 if the display should remain unlit unless a key is pressed. The backlighting
then turns off again after a period of keypad inactivity. Note that when a key is
pressed, display backlighting turns on for all keypads in that partition.
1*45 Exit Delay
Sounding
Enter 1 if beeps from the keypads during exit delay is desired. Enter 0 for no
keypad sound during exit delay.
1*47 Chime On
Ext. Siren
Enter 1 for chime annunciation using the external alarm sounder. If not desired,
enter 0.
1*52 Send Cancel
If Alarm + OFF
Enter 1 if no report restriction is desired. Enter 0 if cancel reports are to be sent
within Bell Timeout period only.
1*76 Access Control
Relay
The system can be programmed to provide user activated access control. If
enabled, the assigned relay will pulse for 2 seconds when the user enters his
code and presses "0". Enter the relay number (00-08) for the relay that will be
used for access control. Enter 00 if not used in this partition.
3rd Page Fields
2*18 Enable GOTO
For This Partition
Enter 1 if this partition is to be accessed by a GOTO command. Otherwise enter
0.
2*20 Enable
J7 Triggers
By Partition
0=disable for displayed partition; 1=enable for displayed partition