Bypassing Zones Enter code + BYPASS [6] + zone number. To
automatically bypass all faulted zones, use "Quick
Bypass" method: Enter code + BYPASS + [#].
Chime Mode Enter code + CHIME [9]. To turn chime mode off, enter
code + CHIME again.
SUMMARY OF ARMING MODES
ÊÊMode Features For Each Arming Mode
Exit Delay Entry Delay Perimeter Armed Interior Armed
ÊÊAWAY Yes Yes Yes Yes
ÊÊSTAY Yes Yes Yes No
ÊINSTANT Yes No Yes No
ÊMAXIMUM Yes No Yes Yes
Access Control If programmed, one relay may be used for access control. To activate this relay,
the user enters his user code + [0]. The designated relay will pulse for 2 seconds.
Each partition can have its own output device. The trigger will occur on the device
tied to the partition for the keypad on which the keys were pressed. The access
control relay is programmed in partition-specific field 1*76.
Partition "GOTO"
Commands
Each keypad (and the 4285 Phone Module) is assigned a default (home) partition
for display purposes, and will show only that partition's information. To see
information for another partition, or perform system functions in another partition,
use the GOTO command (code + [*] + partition number 0-2). The keypad will
remain in the new partition until directed to go to another partition, or until 120
seconds has elapsed with no keypad activity.
For example: 4-1-4-0 + * + [1] = GOTO partition 1
4-1-4-0 + * + [2] = GOTO partition 2
4-1-4-0 + * + [0] = GOTO home partition (i.e. partition defined in
device Êprogramming for this keypad)
View Capabilities
Of A User (Alpha
Keypads Only)
The keypad will display the partitions that user is authorized for, the user number,
and the authority level for all partitions authorized. Enter code + [*] + [*]. The
user's capabilities in each authorized partition will typically be displayed as
follows:
Part. 1 WHSE
User 01 Auth.=1.
The user's Open/Close report capability is shown by the
dot following the authority level. If Open/Close is not
enabled for a user, the dot will not appear.
Viewing Downloaded
Messages
(Alpha Keypads Only)
Users may occasionally receive messages on the keypad display from their
installation company. When this occurs, the keypad will display "Message. Press
0 for 5 secs.". Instruct the user to press and hold the 0 key to display the central
station's message. The system must be in the READY state to view these
messages.
Using The Built-In User's
Manual
(Alpha Keypads Only)
An abbreviated User's Manual is stored in the system's memory, and can be
particularly useful to the end user if the printed User's Manual is not conveniently
accessible when the user needs to perform a seldom used and unfamiliar system
procedure. The Built-in User's Guide is displayed by simply pressing any of the
function keys (e.g., OFF, AWAY, STAY, MAXIMUM, BYPASS, INSTANT, CODE,
TEST, READY, #, and CHIME) for approximately 5 seconds and then releasing it.
Abbreviated instructions relative to the key that has been pressed will then be
displayed (2 lines of text are displayed at a time). This function operates in either
the armed or the disarmed state.
Displaying Descriptors
(Alpha Keypads Only)
The Alpha Keypads can display all programmed descriptors, which is useful to the
installer when checking entries, and can be helpful to the user when there is a
need to identify zones. To display descriptors, the keypads must display a
SYSTEM READY message. Press and hold the READY key until the built-in
instructions for that key appear, then release the key. The zone descriptors will
appear one at a time, for about 2-3 seconds each. For faster viewing, press the
READY key to display the next descriptor in numerical order and so on. When all
descriptors have been displayed, the Control will exit display mode. To exit
display mode before all descriptors have been displayed, enter the security code
and press the OFF key.