Ð 7 Ð
8. The system will search for the next zone that does not have a serial
number associated with it. If one is found, the prompt in step 5, along
with the appropriate zone number, will be displayed. Follow steps 5 and
6 for the remaining zones.
After all zones have been displayed, whether enrolled or not, the "ENTER ZN
NO." prompt will appear. Enter "00" to exit the Sequential mode and return
to data field programming mode.
When you have finished programming all zones, test each using the system's
TEST mode. Do not use the Transmitter ID Sniffer mode for this, as it will only
check for transmission of one zone on a particular transmitter, NOT the zones
assigned to each additional loop, and will NOT verify polling loop type.
RF SERIAL NUMBER CLEAR MODE (#93)
This mode may be used in the event that an undesired transmitter has been enrolled during sequential
enrolling, causing each subsequent serial number to be assigned to an incorrect zone. Performing this
operation will delete all RF serial numbers, leaving all other zone information intact. You may then return to
Sequential mode to re-enroll wireless transmitters.
The RF Serial Number Clear mode will
not
delete polling loop serial numbers.
To clear all RF wireless serial numbers, do the following:
1. Enter Programming mode [Installer Code] + 8 + 0 + 0 on an alpha
keypad. Enter RF Serial Number Clear mode by pressing #93. Press 0
repeatedly until the "CLEAR RF SERIAL #?" prompt is displayed as
follows:
CLEAR RF SERIAL#?
1 = YES, 0 = NO 0
2. Enter "1" to clear all RF wireless serial numbers. The "ARE YOU SURE?"
prompt is displayed as follows:
ARE YOU SURE?
1 = YES, 0 = NO 0
3. Enter "1" to clear all RF serial numbers. Re-enter the Sequential mode to
enroll wireless transmitters.