Guardian Technologies N7001V2 Smoke Alarm User Manual


 
Ð 45 Ð
Section 3. DATA FIELD PROGRAMMING
PROGRAMMING SYSTEM-WIDE (GLOBAL) DATA FIELDS
General Procedure The global (i.e. non partition-specific) programming fields are grouped into three
sets (referred to as "pages"), as represented in the diagram below. The first page
of fields is accessed automatically after entering a field number. To access the
other pages of fields (indicated on the programming form by a "1" or "2" in front of
the 2-digit field address), press *94. Note that the alpha keypads display the
words ALT PROGRAM MODE along with a "1" or "2", depending on which page
of programming fields are accessed, to indicate the higher page of fields. To
return to the previous page of fields, press *99.
Enter programming mode
(installer code + [8] + [0] + [0])
Enter the first field number (ex. *00, installer's code)
to move to first page
First Page of fields
(*00-*90)
press *99 or *98
to exit program
mode
press *94 to move to 2nd page press *99 to move back to 1st page
second page of fields
(1*01-1*76)
press *94 to move to 3rd page press *99 to move back to 2nd page
third page of fields
(2*00-2*21)
To program specific data fields, press [*] plus the 2-digit field address,
then make the required entry. The keypad will beep when a field has been
completely programmed and will automatically display the next field in sequence.
Partitioned programming fields are skipped (refer to PARTITIONING
PROGRAMMING paragraph). If the number of digits that you enter in the data field
is less than the maximum permitted (ex. phone number), the keypad displays the
last entry and waits. To proceed, the next data field to be programmed must be
entered manually (ex. press [*][0][5]).
To view the contents of a data field, press [#] plus the 2-digit field
address. The field's entries will be displayed, but no changes can be made.
In case of errors: If an address is improperly entered, the keypad will display
FC. If a program entry is improperly entered (for example, a larger number than
that which is permitted), the keypad display will go blank. In either case, simply re-
enter the correct number.
SUMMARY OF DATA FIELD PROGRAMMING COMMANDS
*94 Next page of fields
*99 Previous page of fields or exit programming mode with no installer
lockout
*91 Select partition for programming partition-specific fields
#93 Enter Zone/Alpha/Device Programming mode
*98 Exit programming mode with installer code lock-out