Ð 3 Ð
10 LOOP #
1
10. The cursor should now be flashing on the loop number. The default is
"1." To accept this, press [✱]. If a different loop number is being used on
this device, enter the loop number (1-4) and press [✱] to continue (see
the loop designations for various RF transmitters on page 8 of this
addendum). The loop number must be entered here, whether
using Zone Programming or Sequential Mode to "enroll"
serial numbers. If you want to delete the serial number, enter "0" and
press [✱]. The system will then prompt, "DELETE S/N?" Press the "1"
(YES) key to complete the delete sequence. This process deletes the
serial number only,
not
the loop number. The assumption is that the
proper loop number was programmed, but the wrong serial number was
enrolled.
10 LEARN S/N?
1 = YES, 0 = NO 1
11. If the device’s serial number has not been previously “enrolled,” you may
enter the enrollment mode now by either entering "1" (YES)
or
by
pressing the upper left-hand button of the program tool. If using the
program tool, move to the physical location of the device to
be enrolled before pressing the button. A single short beep will
verify that the button has been pressed. The system will respond to the
first serial number transmitted after the [1] key on the keypad or the
button of the program tool is pressed. Enter "0" (NO) to enroll later. (If
"0" is entered, go to step 14.)
10 INPUT S/N
Axxx-xxxx
12. This prompt is displayed if "1" (YES) is entered in response to the "Learn
S/N?" prompt. The serial number may be enrolled by one of two
methods:
a) Enter the 7-digit serial number printed on the transmitter using an alpha
keypad
or
b) Activate the device by faulting
or
restoring the input you wish to use
for that zone (e.g., press a button, open or close a door, etc.).
10 INPUT S/N
A022-4064
The system will enroll the serial number of the first device heard.
If the serial and loop number combination is already present in the system,
the keypad will sound a single long beep and display the word "DUPLICATE"
along with the serial number, and the number of the zone containing the
serial/loop number combination.
13. The system will then enter an optional confirmation mode so that the
operation of the actual programmed input can be confirmed. Activate the
loop input or button that corresponds to this zone. We recommend
that you confirm the programming of every device before
proceeding to the next zone.
10 CONFIRM RF:1
A022-4064 1
When the system sees activity on the appropriate input, it will beep three
times and display the confirmation message.