Guardian Technologies N7001V2 Smoke Alarm User Manual


 
Ð 8 Ð
Descriptors
¥ All programmed descriptors can be displayed (one at
a time) by pressing and holding the READY key for 5
seconds, then releasing the key. This serves as a
check for installers to be sure all descriptors are
entered properly.
Event Logging
¥ Event Logging feature keeps record of up to 100
events.
Access Control
¥ Provides user-activated access control command
which pulses a relay output for controlled opening of
access doors (e.g. lobby door).
#70 End User Relay Commands
¥ Allows end users to manually turn on/off relay/X-10
module outputs to control lights or other devices via
keypad or phone module.
Cabinet
¥ Large cabinet with removable door for easier
installations.
Programming Features
¥ Programming can be performed at the office prior to
installation, or on the job site directly from the
keypad.
¥ Can be downloaded from a remote location or at the
job site (using a PC/laptop with 4100SM Serial
Module) by using the AdemcoÕs V-Link
¨
downloading software (Rev. 4 or higher) or AdemcoÕs
Compass
Windows downloading software.
¥ The Control is pre-programmed with a set of standard
values that is designed to meet the needs of many
installations. These values, however, can be
changed to suit the needs of any particular
installation.
¥ The Control can also be pre-programmed by the
installer with one of four standard communication
default programming values, thus further saving time
and effort.
Installer Code
¥ Installer code override feature. Installer code will
disarm system only if it was used to arm the system.
Prohibit Program Mode Entry
¥ If desired, entry to program mode via [*] + [#] within
30 seconds of power up can be disabled.
Alpha Descriptors
¥ All zones and partitions can be assigned
descriptions.
¥ The letter "s" or " 's " can be added to descriptors.
Relay Voice Descriptors
¥ Separate vocabulary for annunciating relay output
descriptors when using a phone module to activate
relays.
Custom Words
¥ Up to 20 custom words can be added to the built-in
vocabulary.
Voice Substitute Custom Words
¥ Provides a means of annunciating substitute words
for the phone module whenever a custom word is
used for alpha keypad displays.
Downloading
¥ Direct wire downloading can be done without a
modem, by using a PC or Laptop computer and
4100SM Module.
#93 Menu Mode
¥ Easy programming of zones using the user friendly
#93 Menu Mode.
Communication Features
Communication
¥ Ademco low speed, SESCOA/RADIONICS, Ademco
Express, Ademco High Speed, Ademco Contact ID.
Comm. Fields
¥ Easy programming for communication fields. Simply
enter the report code for each zone.
Comm. Defaults
¥ Communication defaults can be loaded anytime, and
does not affect non-communication program fields.
Zone Reports
¥ All 64 zones can report to a central station using any
standard reporting format.
Callback
¥ Callback defeat option for downloading.
Real-Time Clock
¥ Real-Time clock for time related functions.
NOTE: 6139 or 6139AV alpha keypad must be used
to set clock, or it can be set using Downloader
software.
AC Loss Reporting
¥ Random AC Loss and AC Restore reporting option
sends report randomly from 10-40 minutes after AC
loss, to help prevent central stations from receiving
an overload of reports due to area blackouts.
Test Reporting
¥ Intelligent test reporting option means test reports
will not be sent if any other report was sent within the
programmed test report interval.
Split/Dual Reporting
¥ Split/Dual reporting communicator options available.
Cancel Report
¥ Option to allow a cancel report to be sent, even after
Bell Time-out has ended.
Voltage Triggers
¥ Used to interface with LORRA or other devices.
¥ PC Downloader can command output voltage
triggers to pulse on for 2 seconds.
Phone Numbers
¥ Primary and secondary phone number capability.
¥ Can program different formats for each phone
number.