DIP SWITCH TABLES FOR 5700 RF SYSTEM WIRELESS DEVICES
HOUSE ID (1 SHOWN)
HOUSE ID (1 SHOWN)
HOUSE ID (1 SHOWN)
123456
UP
DN
12345
UP
DN
12345678
UP
DN
12345678910
UP
DN
5706/5707 SMOKE
DETECTORTRANSMITTER
5775 PIR
DETECTOR/TRANSMITTER
HOUSE ID
SWITCH SETTING FOR ALL
DEVICES EXCEPT 5716
5727 KEYPAD
DEVICE
ID
DIP SWITCH POSITION
12345
1
UP UP UP UP
2UPUPUPUP
3UPUPUP
4 UP UP UP UP
5UPUPUP
6UPUPUP
7UPUP
8 UP UP UP UP
9 UP UP UP
10 UP UP UP
11 UP UP
12 UP UP UP
13 UP UP
14 UP UP
15 UP————
16 —UPUPUPUP
17 —UPUPUP—
18 UP UP UP
19 UP UP
20 UP UP UP
21 UP UP
22 UP UP
23 UP
24 UP UP UP
25 UP UP
26 UP UP
27 UP
28 UP UP
29 UP
30 ————UP
31 —————
BIT
VALUE: 16 8 4 2 1
DIP
SIDE
VIEW (
UP
)
SIDE
VIEW (
UP
)
SIDE
VIEW (
UP
)
SIDE
VIEW
(
DN
)
5701 PANIC TRANSMITTER
POS.6 UP= XMTR ID 62
DN= XMTR ID 63
DIP
XMTR ID
FIXED AT
“00”
XMTR ID
(48 SHOWN)
XMTR
ID
DIP SWITCH POSITION
678
48 UP UP UP
49 UP UP
50 UP UP
51 UP
52 UP UP
53 UP
54 UP
55
XMTR
ID
DIP SWITCH POSITION
6789
32 UP UP UP UP
33 UP UP UP
34 UP UP UP
35 UP UP
36 UP UP UP
37 UP UP
38 UP UP
39 UP———
40 —UPUPUP
41 UP UP
42 UP UP
43 UP
44 UP UP
45 UP
46 UP
47 ————
}
DIP
HOUSE ID (1 SHOWN)
UP = PULSE COUNT
— = INST. MODE
XMTR ID
(32 SHOWN)
}
MIRROR
DIP
XMTR
ID
DIP SWITCH POSITION
67891011
1 UPUPUPUPUP—
2 UPUPUPUP—UP
3 UPUPUPUP—
4 UP UP UP UP UP
5UPUPUPUP
6UPUPUPUP
7UPUPUP
8 UP UP UP UP UP
9 UP UP UP UP
10 UP UP UP UP
11 UP UP UP
12 UP UP UP UP
13 UP UP UP
14 UP UP UP
15 UP UP
16 UP—UPUPUPUP
17 UP UP UP UP
18 UP UP UP UP
19 UP UP UP
20 UP UP UP UP
21 UP UP UP
22 UP—UP——UP
23 UP UP
24 UP UP UP UP
25 UP UP UP
26 UP UP UP
27 UP UP
28 UP UP UP
29 UP UP
30 UP————UP
31 UP—————
32 —UPUPUPUPUP
BIT
VALUE: 32 16 8 4 2 1
XMTR
ID
DIP SWITCH POSITION
67891011
33 —UPUPUPUP—
34 —UPUPUP—UP
35 —UPUPUP—
36 UP UP UP UP
37 UP UP UP
38 UP UP UP
39 UP UP
40 UP UP UP UP
41 UP UP UP
42 UP UP UP
43 UP UP
44 UP UP UP
45 —UP——UP—
46 UP UP
47 UP
48 UP UP UP UP
49 U UP UP
50 UP UP UP
51 UP UP
52 UP UP UP
53 UP UP
54 UP UP
55 UP
56 UP UP UP
57 UP UP
58 UP UP
59 UP
60 UP UP
61 ————UP—
62 —————UP
63 ——————
BIT
VALUE 32 16 8 4 2 1
5715
UNIVERSAL TRANSMITTER
5711/5711WM
DOOR/WINDOW TRANSMITTER
1 2 3 4 5 6 7 8 9 10 11 12
UP
DN
XMTR ID
(33 SHOWN)
}
POS.12: UP = N.O.
— = N.C
(Avoid ID 32-37 with N.O.)
SIDE
VIEW
(
DN
)
12
}
POS.1: UP = NORMAL RESPONSE
DN = FAST RESPONSE
POS. 2:UP = NO COVER TAMPER
DN = COVER TAMPER (use N.C. setting)
DIP
DIP
TERMINAL
BLOCK
DIP
HOUSE ID (1 SHOWN)
HOUSE
ID
DIP SWITCH POSITION
54321
1 UP UP UP UP
2 UP UP UP UP
3—UPUPUP
4 UP UP UP UP
5—UPUPUP
6UPUPUP
7 UP UP
8UPUPUPUP
9 UP UP UP
10 UP UP UP
11 UP UP
12 UP UP UP
13 UP UP
14 UP UP
15 ————UP
16 UP UP UP UP
17 —UPUPUP—
18 UP UP UP
19 UP UP
20 UP UP UP
21 UP UP
22 UP UP
23 UP
24 UP UP UP
25 —— UP UP
26 UP UP
27 UP
28 UP UP
29 UP
30 UP————
31 —————
BIT
VALUE: 1 2 4 8 16
TRANSMITTER
ID
DIP SWITCH POSITION
654321
1 UP UP UP UP UP
2 UP UP UP UP UP
3 — —UPUPUPUP
4 UP UP UP UP UP
5—UPUPUPUP
6UPUPUPUP
7 UP UP UP
8 UP UP UP UP UP
9 UP UP UP UP
10 UP UP UP UP
11 UP UP UP
12 UP UP UP UP
13 UP UP UP
14 UP UP UP
15 UP UP
16 UP UP UP UP UP
17 —UPUPUP—UP
18 UP UP UP UP
19 UP UP UP
20 UP UP UP UP
21 UP UP UP
22 UP UP UP
23 UP UP
24 UP UP UP UP
25 UP UP UP
26 UP—UP——UP
27 UP UP
28 UP UP UP
29 UP UP
30 UP————UP
31 —————UP
32 UP UP UP UP UP
33 —UPUPUPUP—
34 UP UP UP UP
35 UP UP UP
36 UP UP UP UP
37 UP UP UP
38 UP UP UP
39 UP UP
40 UP UP UP UP
41 UP UP UP
42 UP UP UP
43 UP UP
44 UP UP UP
45 —UP——UP—
46 UP UP
47 ————UP—
48 UP UP UP UP
49 —UPUPUP—
50 UP UP UP
51 UP UP
52 UP UP UP
53 UP UP
54 UP UP
55 UP
56 UP UP UP
57 UP UP
58 UP UP
59 UP
60 UP UP
61 UP
62 UP—————
63 ——————
BIT
VALUE: 1 2 4 8 16 32
654321
UP
DN
POS. 6: UP = N.O.
DN = N.C.
UP
SW3
654321
XMTR ID (33 SHOWN)
HOUSE ID (1 SHOWN)
UP
SW4
SIDE
VIEW (
UP
)
DIP
DIP
SW4
SW3
TERMINALS
5716 DOOR/WINDOW TRANSMITTER
IMPORTANT
SET SWITCHES WITH
BATTERYREMOVED
For 5700 series transmitters not shown in this table, refer to the instructions accompanying each transmitter.
DIP SWITCH TABLES FOR 5700 SERIES WIRELESS DEVICES