Wireless Options (cont.)
1*57 Enable 5800
RF Button
Global Arm
Enter 1 to have the system arm/disarm in accordance with the button's user's
global arming settings. Enter 0 if the button is not to be used to global arm the
system (however, home partition arming will still occur).
1*58 Enable 5800
RF Button
Force Bypass
Enter 1 to allow the RF Button user to force bypass all faulted zones. When
attempting to arm the system, the keypad will beep once after pressing the
button, if any faulted zones are present. If this feature is enabled, the user should
then press the button again within 4 seconds to force bypass those zones and
arm the system. Must be disabled for UL installations.
Partitioning Options
2*00 Number Of
Partitions
Enter the number of partitions 1-2 to be used in the system.
2*17 Number Of User
Codes Per
Partition
Enter 01-69 for each partition used in the system. Enter 01 for an unused
partition. Total number of user codes in the system must be less than or equal to
70. Note that one user number is automatically assigned (installer code) to each
partition, regardless of whether that partition has been enabled.
2*19 Use Partition
Descriptors
Enter 1 if partition descriptors will be programmed. If enabled, certain keypad
displays will include a partition number and the partition descriptor (if programmed
in #93 Menu Mode). Entering 0 causes the keypads to display a non-partitioned
system type of display (no partition number will appear).
Relay Output Options
SECOND PAGE FIELDS
1*74 Relay Timeout
XX Minutes
Enter the relay timeout, 0-127 in multiples of 2 minutes, desired for #93 Menu
Mode Relay Programming output command "56" (refer to the #93 Menu Mode
section in this manual).
1*75 Relay Timeout
YY Seconds
Enter the relay timeout, 0-127 seconds, desired for #93 Menu Mode Relay
Programming command "57" (refer to the #93 Menu Mode section in this
manual).
Real-Time Clock Options
THIRD PAGE FIELDS
2*01 Daylight
Savings Time
Start/End Month
Enter the months 00-12 in which daylight savings time starts and ends. Enter
00, 00 if daylight savings time does not apply to the user's region. Standard
setting for U.S. is 04,10.
2*02 Daylight
Savings Time
Start/End
Weekend
Enter the start and end weekends for daylight savings time as follows: 1=first;
2=second; 3=third; 4=fourth; 5=last; 6=next to last; 7=third from last. Standard
setting for U.S. is 01,05.
Event Logging Options
SECOND PAGE FIELDS
1*70 Event Log
Types
Enter 1 for each of the types of events for which event logging is desired, as
shown on the programming form. Otherwise enter 0.
1*71 12/24 Hour Time
Stamp Format
Select the type of time stamping desired: 0 = standard 12 hour; 1 = 24 hour