Ð 5 Ð
00 PROG AS BR:3
A123-4567 3
In this example, the serial number is A123-4567. Once enrolled, the
upper left-hand button of the program tool can be pressed to ready the
system for enrolling a transmitter into the system.
The serial number for the program tool will only remain in
the system until the programming mode is exited.
(Entering ✱97 will not delete the tool.)
Press [✱] to continue.
Pressing the # key on the keypad will cause the system to back up to the
"PROGRAM TOOL ?" prompt.
TECHNOLOGY TYPE
WIRELESS 0
Default ↑
4. Enter the type of device(s) to be enrolled as follows:
0 = Wireless (Default)
1 = Polling Loop
2 = Both
Press [✱] to continue.
ENTER ZN NO.
(00 = QUIT) 10
Zone Number Entered ↑
5. Enter the first zone number to be enrolled (e.g., zone 10).
Press [✱] to continue.
The system will, starting with this zone number, search for the first device
which has
all
of the following attributes pre-programmed in Zone
Programming:
a) An input type of RF, UR, BR, or SL (if serial polling loop
devices enabled) programmed
b) A loop number programmed
c) No serial number programmed
If the first zone number entered does
not
have one or more of the above
attributes, the system will search its database for the first zone that does and
will display it on the next screen.
10 INPUT S/N
Axxx xxxx
6. This prompt is displayed when the system has found the next zone which
needs to be enrolled. The system will respond to the first serial number
transmitted after the [✱] key on the keypad or the button of the program
tool is pressed. A single short beep will verify that the button has been
pressed. A serial number may be enrolled by one of two methods:
a) Enter the 7 digit serial number printed on the device.
or
b) Activate the device by faulting or restoring the input you wish to use for
that zone (e.g., press a button, open or close a door, etc.).