Ð 2 Ð
ENTER ZN NO.
00 = QUIT 10
Zone 10 entered
↑
4. Enter the zone number that you wish to program. As an example, zone
10 is shown here. Press [✱] to continue.
10 ZT P RC IN:L
00 – –– ––: –
5. A display will appear, showing a summary of that zone's programming. If
the zone is not programmed, the display will appear as shown here. If
checking a zone's programming, and it is programmed satisfactorily, press
[#] to back up one step and enter another zone number, if desired.
Otherwise, press [✱] to continue.
↓ Zone Number
10 ZONE TYPE
Perimeter 03
Entry for Zone Type 03
shown
6. Each zone must be assigned a zone type, which defines the way in which
the system responds to faults in that zone. Enter the zone type desired
(or change it, if necessary). Available zone types are listed below.
00 = Assign For Unused Zones
01 = Entry/Exit #1, Burglary
02 = Entry/Exit #2, Burglary
03 = Perimeter, Burglary
04 = Interior Follower, Burglary
05 = Trouble Day/Alarm Night
06 = 24 Hr Silent
07 = 24 Hr Audible
08 = 24 Hr Aux
09 = Fire
10 = Interior Delay, Burglary
20 = Arm–Stay*
21 = Arm Away*
22 = Disarm*
23 = No Alarm Response
(EX: Relay activation)
* These are special zone of types used with 5800 series wireless push-button
units which will result in arming the system in the STAY or AWAY mode, or
disarming of the system, depending on the selection made.
Press [✱] to continue.
10 PARTITION
2
7. Enter the partition number you are assigning this zone to.
Press [✱] to continue.
10 REPORT CODE
1st 03 2nd 12 3C
8. Enter the report code. The report code consists of 2 hexadecimal digits,
each in turn consisting of 2 numerical digits. For example, for a report
code of "3C", enter [0][3] for "3" and [1][2] for "C."
(Refer to
System Communication
section in the applicable Installation
Instructions for more information about report codes and report code
formats.)
Press [✱] to continue.
10 INPUT TYPE
RF Xmitter 3
9. Enter the RF transmitter or serial number polling loop input device type as
follows:
3 = RF (supervised RF transmitter)
4 = UR (unsupervised RF transmitter)
5 = BR (button type RF transmitter - unsupervised)
6 = SL (serial polling device)
(Refer to the Installation Instructions for more information about input
types.)
Press [✱] to continue.