Guardian Technologies N7001V2 Smoke Alarm User Manual


 
Ð 78 Ð
COMMUNICATION DEFAULTS for ADEMCO EXPRESS FORMAT (*94 then *81)
*45 PRIMARY FORMAT 3 Ê Ademco Express
*46 LOW SPEED FORMAT (Primary) 0 Ê
*47 SECONDARY FORMAT 3 Ê Ademco Express
*48 LOW SPEED FORMAT (Sec.) 0 Ê
*49 CHECKSUM VERIFICATION 0 Ê
No checksum Primary Secondary
*50 SESCOA/RADIONICS SELECT 0 Ê Radionics
*51 DUAL REPORTING 0 Ê no
*52 STANDARD/EXPANDED REPORT FOR PRIMARY
standard
Alarm Rstr Bypass Trbl Opn/Cls Low Bat
*53 STANDARD/EXPANDED REPORT FOR SECONDARY
standard
Alarm Rstr Bypass Trbl Opn/Cls Low Bat
ALARM REPORT CODE & ID DIGITS FOR ZONES 1-32 & SUPERVISORY & RESTORE CODES
*54 CODE *55 ID *56 CODE *57 ID *58
1 Ê1|0Ê
Ê0|1Ê 9 Ê1|0Ê Ê0|9Ê Ê1|4Ê Alarm Rst.
2 Ê1|0Ê Ê0|2Ê 10 Ê0|1Ê Ê1|0Ê Ê0|0Ê Trouble
3 Ê1|0Ê Ê0|3Ê 11 Ê0|1Ê Ê0|1Ê Ê0|0Ê Trble Rst.
4 Ê1|0Ê Ê0|4Ê 12 Ê0|1Ê Ê0|2Ê Ê0|0Ê Bypass
5 Ê1|0Ê Ê0|5Ê 13 Ê0|1Ê Ê0|3Ê Ê0|0Ê Bypss Rst.
6 Ê1|0Ê Ê0|6Ê 14 Ê0|1Ê Ê0|4Ê
7 Ê1|0Ê
Ê0|7Ê 15 Ê0|1Ê Ê0|5Ê
8 Ê1|0Ê
Ê0|8Ê 16 Ê0|1Ê Ê0|6Ê
*59 CODE *60 ID *61 CODE *62 ID *63
17 Ê0|1Ê
Ê0|7Ê 25 Ê0|2Ê Ê0|5Ê Ê1|4Ê Alarm Rst.
18 Ê0|1Ê Ê0|8Ê 26 Ê0|2Ê Ê0|6Ê Ê0|0Ê Trouble
19 Ê0|1Ê Ê0|9Ê 27 Ê0|2Ê Ê0|7Ê Ê0|0Ê Trble Rst.
20 Ê0|2Ê Ê1|0Ê 28 Ê0|2Ê Ê0|8Ê Ê0|0Ê Bypass
21 Ê0|2Ê Ê0|1Ê 29 Ê0|2Ê Ê0|9Ê Ê0|0Ê Bypss Rst.
22 Ê0|2Ê Ê0|2Ê 30 Ê0|3Ê Ê1|0Ê
23 Ê0|2Ê
Ê0|3Ê 31 Ê0|3Ê Ê0|1Ê
24 Ê0|2Ê
Ê0|4Ê 32 Ê0|3Ê Ê0|2Ê
ALARM REPORT CODE & ID DIGITS FOR ZONES 33-64 & SUPERVISORY & RESTORE CODES
*64 CODE *65 ID *66 CODE *67 ID *68
33 Ê0|3Ê
Ê0|3Ê 41 Ê0|4Ê Ê0|1Ê Ê1|4Ê Alarm Rst.
34 Ê0|3Ê Ê0|4Ê 42 Ê0|4Ê Ê0|2Ê Ê0|0Ê Trouble
35 Ê0|3Ê Ê0|5Ê 43 Ê0|4Ê Ê0|3Ê Ê0|0Ê Trble Rst.
36 Ê0|3Ê Ê0|6Ê 44 Ê0|4Ê Ê0|4Ê Ê0|0Ê Bypass
37 Ê0|3Ê Ê0|7Ê 45 Ê0|4Ê Ê0|5Ê Ê0|0Ê Bypss Rst.
38 Ê0|3Ê Ê0|8Ê 46 Ê0|4Ê Ê0|6Ê
39 Ê0|3Ê
Ê0|9Ê 47 Ê0|4Ê Ê0|7Ê
40 Ê0|4Ê
Ê1|0Ê 48 Ê0|4Ê Ê0|8Ê
*69 CODE *70 ID *71 CODE *72 ID *73
49 Ê0|4Ê
Ê0|9Ê 57 Ê0|5Ê Ê0|7Ê Ê1|4Ê Alarm Rst.
50 Ê0|5Ê Ê1|0Ê 58 Ê0|5Ê Ê0|8Ê Ê0|0Ê Trouble
51 Ê0|5Ê Ê0|1Ê 59 Ê0|5Ê Ê0|9Ê Ê0|0Ê Trble Rst.
52 Ê0|5Ê Ê0|2Ê 60 Ê0|6Ê Ê1|0Ê Ê0|0Ê Bypass
53 Ê0|5Ê Ê0|3Ê 61 Ê0|6Ê Ê0|1Ê Ê0|0Ê Bypss Rst.
54 Ê0|5Ê Ê0|4Ê 62 Ê0|6Ê Ê0|2Ê
55 Ê0|5Ê
Ê0|5Ê 63 Ê0|6Ê Ê0|3Ê
56 Ê0|5Ê
Ê0|6Ê 64 Ê0|6Ê Ê0|4Ê
ALARM REPORT CODE & ID DIGITS FOR RF RCVRs & PANICS, & THEIR SUPV. & RESTORE CODES
*74 CODE *75 ID *76 CODE *77 ID *78
87 Ê0|8Ê
Ê0|7Ê 89 Ê0|8Ê Ê0|9Ê Ê1|4Ê Alarm Rst.
88 Ê0|8Ê Ê0|8Ê 90 Ê0|9Ê Ê1|0Ê Ê0|0Ê Trouble
91 Ê0|9Ê Ê0|1Ê Ê0|0Ê Trble Rst.
Duress
Ê1|3Ê Ê1|3Ê Ê0|0Ê Bypass
93 Ê0|9Ê Ê0|3Ê Ê0|0Ê Bypss Rst.
97 Ê0|9Ê Ê0|7Ê
95 Ê0|9Ê Ê0|5Ê (1 + * or A key)
96 Ê0|9Ê Ê0|6Ê (3 + # or C key)
99 Ê0|9Ê Ê0|9Ê (* + # or B key)
NOTES: 97= Poll Loop Short; 88 & 90 = RCVR not receiving transmitter
signals. 89 & 91 = RCVR not responding, bad conn. to panel.
87 = 4285 phone module. 93 = VIM fail
SYSTEM NON ALARM CODES
*81 *82
First Digit Second Digit
Close Ê0|0Ê Ê0|0Ê
Open Ê0|0Ê Ê0|0Ê
Low Battery Ê0|0Ê Ê0|0Ê
Low Bat Res. Ê0|0Ê Ê0|0Ê
AC Loss Ê0|0Ê Ê0|0Ê
AC Restore Ê0|0Ê Ê0|0Ê
Test Ê0|0Ê Ê0|0Ê
Power Ê0|0Ê Ê0|0Ê
Cancel Ê0|0Ê Ê0|0Ê
Prog. Tamper Ê0|0Ê Ê0|0Ê
Second digit of each
code applies only to
4+2 or expanded (fields
*52 & *53) formats.
ZONE TYPE RESTORE ENABLES
*79 ZONE TYPES 1-8 All enabled
1Ê 1Ê
12345678
*80 ZONE TYPES 9 &10 1 Ê
All enabled ÊÊÊ9 10