2 - 48
2 MULTIPLE CPU SYSTEM
Table 2.4 Multiple CPU errors which occurs in the Motion CPU (1000 to 10000) (continued)
Occurs CPU LED status
Middle
classification
Error messages
Error
code
Error information
Classification code
Single
composition
Multiple
composition
RUN ERROR
Operating
status of CPU
Diagnostic
timing
3001
3010 —
3012 —
Parameter
PARAMETER
ERROR
3013
File name
—
OFF Flickers Stop
At power
supply ON/
at reset/
at Stop
Run
Always
7000
Module No.
(Note-1) (Note-3)
—
7002 —
Other issue
opportunity CPU
weight occasion error
(MULTI CPU DOWN)
7003
Module No.
(Note-1)
—
OFF Flickers Stop
At power
supply ON/
at reset
Multiple CPU start
error
(MULTI EXE.
ERROR)
7010
Module No.
(Note-1)
—
OFF Flickers Stop
At power
supply ON/
at reset
Multiple
CPU
Multiple CPU start
error
(MULTI CPU
ERROR)
7020
Module No.
(Note-1)
—
ON ON Continue Always
CPU error
except for
PLC CPU
CPU error except for
PLC CPU
(CONT. UNIT
ERROR)
(Note-4) (Note-5)
10000 — Except for PLC CPU ON
ON : System
setting
error/
servo
error
OFF : other
error
Stop : System
setting
error
Continue : other
error
At power
supply ON/
at reset/
at Stop
Run
(Note-1) : CPU No. is stored in slot No. of the common information classification.
(Note-2) : Base No. in "common information classification code" of "error information classification code" is 0 : CPU base, 1 to 7 : Number of extension bases.
(Note-3) : Because a stop error or CPU No. except CPU No. that it was reset becomes MULTI CPU DOWN simultaneously, a stop error or CPU No. except CPU
No. that it was reset may store in the classification of error information depending on timing.
(Note-4) : When an error occurs in the Motion CPU and so on except PLC CPU, if a PC diagnosis is made in the CPU except PLC CPU from GX Developer via
PLC CPU, the error code "10000" is indicated.
(Note-5) : The Motion SFC error detection signal (M2039) turned on at the error detection (SV13/SV22). A self-diagnosis error flag (M9008) and a diagnosis error
flag (M9010) do not turn on at the error detection. The error code "10000" being set in D9008 is reset in the Motion SFC error detection signal (M2039)
ON
OFF (SV13/SV22).
(Note-6) : MOTION RUN LED turns off at the stop error occurrence. (The condition of RUN LED does not change.)