Mitsubishi Electronics Q173HCPU Home Security System User Manual


 
4 - 18
4 AUXILIARY AND APPLIED FUNCTIONS
POINT
Do not change the DIP switch setting during operation.
Be sure to turn off the power supply of the Multiple CPU system to change the DIP
switch setting.
(2) Applicable data into ROM
The data contents batch written to the internal FLASH ROM by ROM writing are
shown below. Backup data except the followings (current position of servomotor in
absolute position system, home position and latch device, etc.) cannot be written
to the internal FLASH ROM.
(a) Content of applicable data into ROM
SV13 SV22 SV43
System setting data
Each parameter for servo control
Servo program
Motion SFC parameter Motion parameter
Motion SFC program Motion program
— Mechanical system program
(Note-1)
— Cam data
(Note-1)
(Note-1) : Mechanical system program and cam data are "applicable data into ROM",
when using the SV22.