Carrier 39L Air Conditioner User Manual


 
Table 13 Keyboard Directory (cont)
SERVICE CONFIGURATIONS
Keyboard Entry Display Description
COOLCOIL
Configuration of cooling
(chilled water coil or DX)
MPG X Master proportional gain
MIG X Master integral gain
MDG X Master derivative gain
SMG X Submaster gain
SCV X Submaster center value
HHL X High humidity limit
SMR X Submaster reference value
SMR X Submaster reference value forced
DXCOOL Configure DX cooling
SMG X Submaster gain
SMG X Submaster gain forced
MSR X Minimum submaster reference
DX1G X Stage 1 Time Guarddevice
DX2G X Stage 2 Time Guard
DX3G X Stage 3 Time Guard
DX4G X Stage 4 Time Guard
DX5G X Stage 5 Time Guard
DX6G X Stage 6 Time Guard
DX7G X Stage 7 Time Guard
DX8G X Stage 8 Time Guard
DX1T X Stage 1 logic type
DX2T X Stage 2 logic type
DX3T X Stage 3 logic type
DX4T X Stage 4 logic type
DX5T X Stage 5 logic type
DX6T X Stage 6 logic type
DX7T X Stage 7 logic type
DX8T X Stage 8 logic type
INLET GV Configuration of inlet guide vanes
MPG X Master proportional gain
MIG X Master integral gain
MDG X Master derivative gain
SMG X Submaster gain
SCV X Submaster center value
SMR X Submaster reference value
SMR X Submaster reference value forced
DX Direct Expansion
OAVP Outside Air Velocity Pressure
SERVICE CONFIGURATIONS
Keyboard Entry Display Description
MIXADMPR Configuration of mixed air damper
MPG X Master proportional gain
MIG X Master integral gain
MDG X Master derivative gain
SMG X Submaster gain
SCV X Submaster center value
MDP X Minimum damper position
SMR X Submaster reference value
SMR X Submaster reference value forced
DPSP X Damper set point
DPSP X Damper set point forced
OAE X Outside air enthalpy
RAE X Return air enthalpy
CNTRL X Damper controlled by
ELECHEAT Configuration of electric heat
MPG X Master proportional gain
MIG X Master integral gain
MDG X Master derivative gain
SMG X Submaster gain
SMR X Submaster reference value
SMR X Submaster reference value forced
NTFC
Configuration of nighttime
free cooling (NTFC)
NTLO X
NTFC lockout temperature (minimum
outside air temperature to operate
NTFC)
NPURGE Configuration of night purge
NPMN X Night purge duration
NPDL X
Night purge low temperature
damper position
NPDH X
Night purge high temperature
damper position
MDP X Minimum damper position
OAC
Configuration of constant
outside air
MPG X Master proportional gain
MIG X Master integral gain
MDG X Master derivative gain
SMG X Submaster gain
SMG X Submaster gain forced
OALV X OAVP sensor low voltage point
OAHV X OAVP sensor high voltage point
OALR X OAVP sensor low voltage reference
OAHR X OAVP sensor high voltage reference
PMF X OAVP sensor probe multiplier factor
MDP X Minimum damper position
SMR X Submaster reference value
SMR X Submaster reference value forced