Carrier 39L Air Conditioner User Manual


 
Table 13 Keyboard Directory (cont)
SCHEDULE
Keyboard Entry Display Description
OVRD X Number of hours to extend
occupied mode of schedule 1
PERIOD 1 Define period 1 of time
schedule 1
OCC X Start of occupied time
UNO X Start of unoccupied time
MON X Monday flag (x = entry code)
(1 = yes, .0 or CLR = no)
TUE X Tuesday flag (x = entry code)
(1 = yes, .0 or CLR = no)
WED X Wednesday flag (x = entry code)
(1 = yes, .0 or CLR = no)
THU X Thursday flag (x = entry code)
(1 = yes, .0 or CLR = no)
FRI X Friday flag (x = entry code)
(1 = yes, .0 or CLR = no)
SAT X Saturday flag (x = entry code)
(1 = yes, .0 or CLR = no)
SUN X Sunday flag
HOL X Holiday flag
Time periods 2-8 of schedule 1
(same elements as period 1, schedule 1)
OVRD X Number of hours to extend
occupied mode of schedule 2
PERIOD 1 Define period 1 of time
schedule 2
OCC X Start of occupied time
UNO X Start of unoccupied time
MON X Monday flag (x = entry code)
(1 = yes, .0 or CLR = no)
TUE X Tuesday flag (x = entry code)
(1 = yes, .0 or CLR = no)
WED X Wednesday flag (x = entry code)
(1 = yes, .0 or CLR = no)
THU X Thursday flag (x = entry code)
(1 = yes, .0 or CLR = no)
FRI X Friday flag (x = entry code)
(1 = yes, .0 or CLR = no)
SAT X Saturday flag (x = entry code)
(1 = yes, .0 or CLR = no)
SUN X Sunday flag
HOL X Holiday flag
Time periods 2-8 of schedule 2
(same elements as period 1, schedule 2)
CV Constant Volume
DX Direct Expansion
VAV Variable Air Volume
SERVICE CONFIGURATIONS
Keyboard Entry Display Description
LOG ON Enter password to log on
LOGGEDON Log on okay
When finished with configuration, log off as follows:
LOGGEDON
Shows that configurations are
available
LOG OFF
LOGD OFF
Log off okay; configurations again
password protected
VERSION Software version
XXX-XX-X Software version number
FACT CFG Factory configuration
TYPE X Unit type (0 = CV,1=VAV)
COOL X Cooling (0 = none, 1 = coil)
DXST X
DX cooling stages 0-8
(enter number)
HEAT X
Heating (0 = none,
1 = hot/steam,
2 = electric heat coil)
EHST X
Electric heat stages 0-8
(enter number)
MIXD X
Mixed air damper (0 = none,
1 = yes, 2 = 2-position)
IAQT X Indoor-air quality type
MATP X Mixed air temperature protection
BUS X
Bus number (factory default
set=0)
ADR X
Element address (factory set
default = 1)
PSW X Password XXXX
UNITS X
English/metric system
(0 = English, 1 = metric)
USER CFG User configuration
NTEN X
Nighttime free cooling
configuration
HUEN X Humidity configuration
OHEN X Occupied heating configuration
RSEN X
Space temperature reset
configuration
DLEN X Demand limiting configuration
FTEN X Fan tracking configuration
OAEN X Constant outside air
NPEN X Night purge
AQEN X Indoor air quality
IAQP X Indoor air quality priority level
OSEN X Optimal start/stop configuration
TSCH X Timed override schedules
TOVR X Timed override values
HEATCOIL Configuration of heating coil
MPG X Master proportional gain
MIG X Master integral gain
MDG X Master derivative gain
SMG X Submaster gain
SCV X Submaster center value
FOV X Fan off value
SMR X Submaster reference value
SMR X Submaster reference value forced
72