Redundant Power Supply 7-5
Required Power
Supply for Various
CoreBuilder
Installations
Table 7-3, which is calculated from Table 7-2, shows the number of
power supplies required (Single or Dual) for various CoreBuilder 7000
installations. The first column describes the particular combination of
cards installed and covers the most common applications. The second
column shows the number of power supplies required if a redundant
switch is not installed; the third column shows the number of power
supplies required if a redundant switch is installed.
7608T Fast Ethernet interface card
8TX Fast Ethernet ports
8 Fast Ethernet ports unoccupied
3C37617 15.3
7662T Fast Ethernet module
2TX Fast Ethernet ports
14 Fast Ethernet ports unoccupied
3C37662 1.4
*The typical power consumption values represent typical traffic, load and line speed of the
CoreBuilder and interface cards
.
Maximum power consumption of the cards is 10% higher
than the typical values, and occurs when all card ports are working at full rate
†A redundant switch has the same power requirements as the active switch
Table 7-2
Typical Power Consumption of CoreBuilder 7000 Family Cards
Table 7-3
Required Power Supply for Various Installations
Cards Installed in CoreBuilder Chassis
No Redundant
Switch
Installed
Redundant
Switch
Installed
Data Center - High-density Fast Ethernet and ATM
CB7000 HD Switching Card
4 X CB7600F Fast Ethernet Interface Card
Dual 90A Dual 90A
CB7000 HD Switching Card
4 X CB7600T Fast Ethernet Interface Card
Single 90A Dual 90A
CB7000 HD Switching Card
3 X 7600F Fast Ethernet Interface Card
1 X 8-port ATM Interface Card
Single 90A Dual 90A
CB7000 HD Switching Card
3 X 7600T Fast Ethernet Interface Card
1 X 8-port ATM Interface Card
Single 90A Single 90A
Data Closet - Ethernet
CB7000 Switching Card
4 X 7436 ATM Interface Card
Single 90A Single 90A