3Com DUA3700-0BAA04 Plumbing Product User Manual


 
Switch Module
4-7
Setting up Switch
Module Hardware
Redundancy
Use the following procedure to set up the switch module hardware
redundancy.
1
Designate and mark the main and redundant switch modules.
2
Insert the switch module you marked as “redundant” in slot 2. Do not
insert the switch module you marked as “main” yet.
3
Turn on the CoreBuilder 7000 family ATM switch.
The switch module in slot 2 becomes active.
4
Run the Integrated Fast Setup procedure (see “Integrated Fast Setup” on
page 6-3) using the LMA command
(9) FST
5
Insert the main switch module in slot 1.
6
Wait five minutes for configuration information to pass between the two
switch modules (see “Switching Module Configuration Database” on
page 7-10 for a list of configuration items that pass between the switch
modules).
7
Reboot the CoreBuilder 7000 family ATM switch using the LMA menu
sequence:
(1) SYS / (7) RBO.
The switch module in slot 1 becomes active.
8
Verify main and redundant switch module status using the LMA
command
(1) SYS / (4) SWM
You should see the following display.
9
Run the Integrated Fast Setup procedure using the LMA command
(9) FST to verify the configuration in the main switch module.
10
Add the following configuration information that did not pass between
the switch modules in step 6 (see “Switching Module Configuration
Database” on page 7-10).
Slot id Slot status Switch type Switch mode Memory size
------- ----------- ---------------- ------------ -----------
1 Occupied 32X32 ATM switch Active 16M
2 Occupied 16x16 ATM switch Redundant 8M