3Com DUA3700-0BAA04 Plumbing Product User Manual


 
4-10
C
HAPTER
4: I
NSTALLING
AND
C
ONNECTING
C
ORE
B
UILDER
M
ODULES
To execute the RESETCFG.BAT file proceed as follows:
a
Perform the LMA command (1) SYS / (3) LOA / (3) LCL / 1 to put the
system in Load Mode: Load.
b
Reboot the switch using the LMA menu command: (1) SYS / (7) RBO.
The switch will reboot in debug mode.
c
Transfer the RS-232 cable to the service port of the main switch
module.
d
From a DOS window on the LMA terminal execute
>
resetcfg com speed
where “com” is the communications port you are using and “speed”
is 115200 for a CoreBuilder 7000HD switch module and 57600 for a
CoreBuilder 7000 switch module.
e
Transfer the RS-232 cable to the service port of the redundant switch
module.
f
Repeat step d)
g
Transfer the RS-232 cable to the console port of the main switch
module.
Switch Module Redundancy Setup
2
Set up the main switch module using the Integrated Fast Setup (see
“Integrated Fast Setup” on page 6-3). Do not reboot the switch from the
Integrated Fast Setup procedure (answer “no” to the prompt).
The main menu appears.
3
Wait for one minute to allow the configuration data to transfer from the
main switch module to the redundant switch module.
4
Reboot the switch using the LMA menu sequence: (1) SYS / (7) RBO. This
causes the configuration data to be recorded in flash memory and also
causes the redundant switch module to become the main switch module.
5
After the switch reboots, answer “no” to the prompt: “Do you wish to
erase the setup parameters”.
6
Run the Integrated Fast Setup procedure as in step 2) to verify that the
setup parameters have been transferred correctly to the second switch
(the Integrated Fast Setup procedure now displays the setup parameters
resident in the second switch module). Press Enter repeatedly to verify
these parameters; do not enter new values.