Raritan Computer Home Security System Home Security System User Manual


 
Chapter 6: Devices, Device Groups, and Ports
56
Column
number
Tag or value Details
9 TCP Port Default is configured in the Admin
Client in Administration >
Configuration > Device Settings tab.
10 Configure All Ports
TRUE or FALSE
Default is TRUE for Dominion PX
devices.
Default is FALSE for all other device
types.
When set to TRUE, all ports are
configured and nodes with the
appropriate out-of-band interface are
created.
When set to FALSE, only ports that
have a corresponding ADD DEVICE-
PORT record in the CSV file are
configured.
11 Allow Direct Access
TRUE or FALSE
Default is FALSE.
This setting is for SX and KX2
version 2.2 or later devices only.
12 Description Optional.
To add a port to the CSV file:
Use the DEVICE-PORT tag only if you add a device with Configure All
Ports set to FALSE, and you want to specify ports individually. The ports
you add must be un-configured in CC-SG when you import the CSV file.
Column
number
Tag or value Details
1
ADD
The first column for all tags is the
command ADD.
2
DEVICE-PORT
Enter the tag as shown. Tags are not
case sensitive.
3 Device Name Required field.
4 Port Type Required field.
Enter the port type as shown here:
KVM, SERIAL, or OUTLET