Chapter 6: Devices, Device Groups, and Ports
55
Devices CSV File Requirements
The devices CSV file defines the devices, ports, and their details
required to add them to CC-SG.
For devices that support power strips connected to a port (SX, KX,
KX2, KSX2), configuring the port will configure the power strip.
If device ports are configured, CC-SG also adds a node with out-of-
band KVM or out-of-band Serial interface for each port.
To add blades, the blade server must be connected to a KX2 device
via a CIM. The KX2 device must either already be added to CC-SG,
or be included in the same CSV file.
Export a file from CC-SG to view the Comments, which include all
tags and parameters needed to create a valid CSV file. See Export
Devices (on page 59).
Follo
w the additional requirements for all CSV files. See Common
CSV File Requirements (on page 333).
To add a device to the CSV file:
Column
number
Tag or value Details
1
ADD
The first column for all tags is the
command ADD.
2
DEVICE
Enter the tag as shown.
Tags are not case sensitive.
3 Device Type
Required field.
Enter the device type as shown here:
KX, KX2, KSX, KSX2, KX101,
KX2-101, IP-Reach, SX, or PX
4 Device Name Required field.
Device names cannot contain
spaces or certain special characters.
Dominion PX device names cannot
include periods. Upon import,
periods are converted to hyphens.
5 IP Address or Hostname Required field.
6 Username Required field.
7 Password Required field.
8 Heartbeat Default is configured in the Admin
Client in Administration >
Configuration > Device Settings tab.