XR500 Series Canadian Programming Guide Digital Monitoring Products
71
aPPendiX
23.12.2
LX-Bus Zone Type Defaults
These are complete spellings of the abbreviations used for the
zone types, such as Night and Exit.
Type -Thesearetheabbreviationsusedforthezonetypes,
such as NT and EX.
Area-ForanAreaorHome/Sleep/AwaywithGuestsystem
thisis1to32.ForanAll/PerimeterorHome/Sleep/Away
system, this is the Interior, Bedroom, or Perimeter. Select the
area for NT, DY, EX, A1, A2, and AR types.
Fire Bell Out -OnlyavailableforFI,FV,andSVzones.Use
any output zone number listed.
Wireless -Thisindicateswirelessequipmentisbeingused.
DMP Wireless -TheseoptionsareforusewiththeDMP1100X
WirelessReceiver.
FA Series Wireless -Theseoptionsareforusewiththe
FA400-DMPRemoteWirelessReceiver.
Message -A=alarmreport,T=troublereport,
L=local,noreport,—(dash)=noreport,
D=doorpropped(WhenSVzoneisconnectedto303Silence/
ResetSwitch),S=sensorreset/alarmsilence,C=early
morning ambush cancel.
Output -Theseare1to6on-boardand500to999off-board
relayoutputs,450to474and480to499wirelessoutputs,D1
toD16,andG1toG20.
Action -Thisselectstheactionoftheoutput:
S=steady,P=pulse,M=momentary,andF=follow
Swinger -Thezonecanbeautomaticallyshuntedaftera
programmed number of trips.
Prewarn -Thisselectsthekeypadaddressthatsoundsthe
entry prewarn for this zone.
Entry Delay-Thisistheentrydelaytimerselectedasthe
default for this zone.
Retard Delay-Providesaprogrammedretardtimebeforean
alarminitiatesfromashortedzone.Whenusedonanarming
zone, the retard delay occurs when the zone is shorted before
the armed state has changed. If the arming zone has Maintain
as the Style, the retard delay also occurs when the zone
returns to a normal state.
Presignal -Providesakeypadtoneforzonesinretarddelay.
Retard must be YES before Presignal can be selected.
Fast Response-Providesa167mszoneresponseinsteadofthe
normal 500ms response.
Cross Zone-Providescrosszoningwithanyofthe574zones.
Priority -Requiresthiszonetobeinanormalcondition
before the area can be armed.
Style - The abbreviations for arming zone style:
TGL=Toggle,ARM=Armonly,DIS=Disarmonly,
STEP=Wirelessarming,MNT=Maint
Style
TGL
ARM
DIS
STEP
MNT
TGL
*OutputOptions:1to6,450to474,480to499,500to999,D1toD16,G1toG20. +=SetretardtoYESbeforeselectingpresignal. =Zonefunctionsnotavailable.
Door Number
0
to
16
0
0
0
0
0
Real-TimeReports
N
or
Y
N
N
N
N
N
Follow Area
0
to
16
0
0
0
0
Priority
N
or
Y
N
N
N
N
N
N
N
N
N
N
CrossZone
N
or
Y
N
N
N
N
N
N
N
N
N
Fast Response
N
or
Y
N
N
N
N
N
N
N
N
N
N
Presignal
1
to
16
+
+
+
+
+
Retard Delay
N
or
Y
N
N
N
N
N
Entry Delay
1
2
3
or
4
1
Prewarn
1
to
16
1-16
Swinger
N
or
Y
Y
Y
Y
N
N
N
N
N
N
N
Armed
Short
Action
S
P
M
F
S
S
S
S
S
S
S
S
S
S
Output *
0
0
0
0
0
0
0
0
0
0
Message
A
T
L
–
D
S
C
A
A
A
A
A
A
A
A
A
A
Armed
Open
Action
S
P
M
F
S
S
S
S
S
S
S
S
S
S
Output *
0
0
0
0
0
0
0
0
0
0
Message
A
T
L
–
D
S
C
A
A
A
A
A
A
A
A
A
A
Disarmed
Short
Action
S
P
M
F
S
S
S
S
S
Output *
0
0
0
0
0
0
0
Message
A
T
L
–D
S
C
–
T
–
A
A
A
A
Disarmed
Open
Action
S
P
M
F
S
S
S
S
S
Output *
0
0
0
0
0
Message
A
T
L
–D
S
C
–
T
–
T
T
FA Series
Wireless
NormallyOpen
N
or
Y
N
N
N
N
N
N
N
N
N
N
N
End-of-Line
N
or
Y
N
N
N
N
N
N
N
N
N
N
N
INT Contact
N
or
Y
N
N
N
N
N
N
N
N
N
N
N
Check-inTime
None
10
30
60
60
60
60
60
60
60
60
60
60
60
60
DMPWireless
1126Sensitivity
Low
or
High
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
1126PulseCount
2
or
4
4
4
4
4
4
4
4
4
4
4
4
1126Disarm/
Disable
N
or
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
1142LED
Operation
N
or
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Supervision Time
0
3
60
240
240
240
240
240
240
240
240
240
240
240
240
1114 Contact
1
2
3
4
1
1
1
1
1
1
1
1
1
1
1
1101 EXT
ContactN/O?
N
or
Y
N
N
N
N
N
N
N
N
N
N
N
1101 Contact
INT
or
EXT
INT
INT
INT
INT
INT
INT
INT
INT
INT
INT
INT
Wireless
N
or
Y
N
N
N
N
N
N
N
N
N
N
N
Fire
Bell
Output *
0
0
0
Area
INT
PERIM
BDRM
or
1
to
32
Type
--
NT
DY
EX
FI
PN
EM
SV
A1
A2
FV
AR
NT
DY
EX
FI
PN
EM
SV
A1
A2
FV
AR
XR500 Series LX-Bus
Zone Information
Assign Disarm condition for NT,
DY, EX, A1, and A2 only.
Assign Prewarn and Entry Delay
for EX only.
Assign Retard and Presignal for
FI, SV, A1, A2, and PN only.
Zone Type Defaults
NIGHT
DAY
EXIT
FIRE
PANIC
EMERGENCY
SUPERVISORY
AUXILIARY1
AUXILIARY2
FIRE VERIFY
ARMING