zone informaTion
19.15
MSG: TROUBLE
Report to Transmit
PressanySelectkeytodisplaythefollowingreportoptions:A,T,L,S,C,and-(dash).
A T L -
ALARM - Select A to send an alarm report to the receiver and activate the bell
output according to zone type. The zone name appears in the panel alarmed zones
and status lists.
TROUBLE - Select T to send a trouble report to the receiver. The zone name
appears in the panel alarmed zones and status lists.
LOCAL - WhenyouselectL,analarmreportisNOTsenttothereceiver.Thebell
output activates and the zone name appears in the panel alarmed zones and status
lists.
- (Dash) - Whenyouselecta–(dash),reportsareNOTsenttothereceiver.Thebell
output does not activate and there is no display in the panel alarmed zones or status
list.Onlytherelayoutputselectedinthenextsectionoperates.
D S C
DOOR PROPPED-SelectingD allows the following operation: The time programmed
intoENTRYDLY4intheSystem Option section begins to count without displaying
on keypad. If the time expires and the zone has not returned to normal, the keypad
troublebuzzerstartsandCLOSETHEDOORappearsonthekeypadsprogrammedinto
thePREWARNADDRESSsection.ThetimeprogrammedintoENTRYDLY4beginsto
count down again internally. If the time expires a second time and the zone has not
returnedtonormal,afaultreportissenttothereceiverandthezonename-OPEN
message displays on the keypads until a code is entered. The bell output does not
activate for the Door Propped operation.
SILENCE/RESET - SelectSwhenthezone(notFI,SV,orFV)isconnectedtoaDMP
Model303Silence/Resetswitch,thezonecanbeusedtosilencethealarmbelland
performasensorresetwithoutusingakeypad.AreportisNOTsenttothereceiver
except for the bell silence report.
CANCEL AMBUSH - Select C for the zone to cancel the Early Morning Ambush timer
and stop an Ambush message from being sent to the receiver. Faulting the zone
takes the place of a second user code being entered at the keypad and is only
availablefornon-retypezones.Areaassignmentforthezonedoesnotaffectthis
option. See Early Morning Ambush in Area Information programming .
19.16
OUTPUT NO: 0
Output Number
YoucanspecifyanyoftheRelayOutputsontheXR500Seriespaneltobeactivated
byazonecondition(1to6,500to999ifModel716used,D1toD16,G1toG20).
The output can be activated regardless of the report to transmit or whether or not
the zone is programmed as local. An output activated by an armed zone is turned
off when the zone area is disarmed by a user.
To enter an output number, press a top row Select key followed by the output
number.PresstheCOMMANDkey.
19.17
OUTPUT: NONE
Output Action
EnteringanOutputNumberdisplaysthisprompt.Thispromptallowsyoutoassign
an output action to the relay: Steady, Pulse, Momentary, or Follow.
Note: Some wireless devices whether powered using an AC adaptor or a battery,
ignore some output action programming.
STD PLS MOM FOLW
STEADY - The output is turned on and remains on until the area is disarmed, an
output cutoff time expires, or the output is reset from the keypad menu.
PULSE - The output alternates one second on and one second off.
Note:ThepulsingrateforaModel716relayattachedtotheLX-Busis1.6seconds.
MOMENTARY - The output is turned on only once for one second.
FOLLOW - The output is turned on and remains on while the zone is in an off
normal,orbadcondition.Whenthezonerestores,theoutputisturnedoff.
After you make the three selections in the sections above, the display prompts you for the same three
selectionsforDisarmedShort,ArmedOpen,andArmedShortconditions.Ifthezoneisa24-hourtype,
onlytheArmedOpenandArmedShortconditionsdisplay.Whenyouhaveprogrammedallofthezone
conditions, the Swinger Bypass selection then dis plays.