DMP Electronics XR500 Home Security System User Manual


 
XR500 Series Canadian Programming Guide Digital Monitoring Products
31
SySTem oPTionS
9.19
WLS AUDIBLE: DAY
WIRELESS AUDIBLE
ANY DAY MIN
Wireless Audible Annunciation
ThisoptiondisplayswhentheHouseCodeenteredisforaDMP1100SeriesWireless
system(1-50).Pressanytoprowkeytoselectthekeypadbuzzerannunciation
method for wireless low battery and missing messages. Select ANY to enable
annunciation anytime. Select DAY to enable annunciation except during sleeping
hours(9PMto9AM).SelectMIN(minimum)toannunciateonlyFireandFireVerify
zonesduringdaytimehours(9AMto9PM).DefaultisDAY.
9.20
KEYPAD PANIC KEYS
ENABLED: NO YES
Enable Keypad Panic Keys
Thisoptionallowsthetwo-buttonpanickeyoperationselectedatthekeypadto
send the Panic, Emergency, or Fire message to the central station receiver. Select
YEStoenablethetwo-buttonpanicoperationtooperate.Todisablethetwo-button
panicoperation,selectNO.DefaultisYES.
9.21
OCCUPIED
PREMISES: NO YES
Occupied Premises
ForAll/PerimeterorHome/Sleep/Awaysystems,selectYEStoallowthepanelto
automaticallydisarmtheinteriorarea(s)whenarmingallareasandaperimeter
zoneisnottrippedduringtheexitdelay.SelectNOtodisablethisfeature.Default
is YES.
Note:WithaHome/Sleep/AwaywithGuestarmingsystem,thisfeatureonlyapplies
to the main system.
9.22
ENHANCED ZONE
TEST: NO YES
Enhanced Zone Test
SelectYEStoallowenhancedzonetestoperation.ThedefaultisNO.
Enhanced operation allows:
• PanicTestandWalkTestfunctionscanberestrictedtooperateonlyduringan
Area 32, Shift 4 schedule if programmed. If no schedule is entered, the walk
test always operates.
• AVerifymessageissenteachtimeazoneistested.Ifazoneistripped
multiple times, a Verify message is sent for each trip. This allows the Central
Station to record the number of devices per zone.
• TheVerifymessageforeachzonetestissentatthetimethetripoccurs
insteadofattheendofWalkTest.
• TheSystemTestBeginandSystemTestEndCentralStationmessagesindicate
the type of zone being tested. The System Test Begin message also includes
the user name and number.
9.23 Dual EOL
SelectYEStoenabletheuseofdual1KEOLresistorsonpanelzonesonetoeight.
ThiszoneoperationisusedformediumorhighriskULCListedapplications.Please
seeDualEOLsectionintheXR500SeriesCanadianInstallationGuideforcomplete
details.SelectNOtodisablethisfeature.DefaultisYES.
9.24
SEND 16 CHAR
NAMES: NO YES
Send 16 Character Names
Thisoptionallowscentralstationstoselectbeingsenteithertherst16characters
ofthenameeldortheentireprogrammedname,upto32characters,foruser
name,userprole,zonename,areaname,outputname,andgroupname.
SelectYEStohavetherst16charactersofthenameeldsenttothecentral
station.SelectNOtosendtheexactnumberofcharactersenteredinthenameeld
from 1 up to the maximum of 32 characters. Default is YES.
Note: Using 32 character names increases the length of the DMP Serial 3 message
fromthepaneltothereceiver.TheSCS-1Rreceiverdoesnotrequireanupdateto
pass these messages to the Host Automation System of the Central Station. Before
usingnameslongerthan16characters,determinewhethertheHostAutomation
SystemofyourCentralStationcanaccept17to32characternames.Ifnot,onlyuse
16characternames.
DUAL EOL NO YES