area informaTion
18.5
CLS CHK NO YES
Closing Check
Select YES to enable the panel to verify that all areas in the system are armed
afterpermanentorextendedschedulesexpire.IftheClosingCheckndsanyareas
disarmed past the sched uled time, the keypads selected to display System Trouble
StatusdisplaysCLOSINGTIME! andemitsasteadybeep.WhenAreaSchedulesisset
toYESinAreaInformation,thespecicareaandnamedisplayfollowedby—LATE.
WhenAutoArmisNO,ifwithintenminutesthesystemisnotarmedorifthe
scheduleisnotextended,aLatetoClosereportissenttotheSCS-1RReceiver.
WhenAutoArmisYES,theareaarms.SeeAutomaticArmingsection.
If the area becomes disarmed outside of any schedule, the Closing Check sequence
occursaftertheLateArmDelaytime.SeeLateArmDelay.
WhenClosingCheckisNOandAutoArmisYES,thesystemimmediatelyarmswhen
the schedule expires. No warning tone occurs.
Inaddition,whenClosingCheckisNO,theoptiontoextendascheduledoesnot
display when the schedule expires.
18.6
CLS CODE NO YES
Closing Code
WhenYESisselected,acodenumberisrequiredforsystemarming.IfNOis
selected, a code number is not required for system arming.
18.7
ANY BYPS NO YES
Any Bypass
WhenYESisselected,zonescanbebypassedwithoutacodenumberduringthe
armingsequence.AcodenumberisalwaysrequiredtousetheBypassZonesoption
from the menu.
18.8
AREA SCH NO YES
Area Schedules
Select YES to allow each area to set its own shift schedules 1 to 4. Enter NO to
provide one set of schedules for this system.
Note:AreaSchedulesarenotdesignedtooperatewithAll/PerimeterorHome/
Sleep/Awaysystems.
18.9
EARLY AMBUSH: 0
Early Morning Ambush (XR500N/XR500E only)
Enterthenumberofminutes(1to15)beforeasilentalarm(EarlyMorningAmbushS33)
issenttothecentralstationusingthearea1accountnumber.Enter0(zero)todisable
this option.
Whenausercodeisenteredtodisarmarea1atakeypadorreaderwithAccess
Areas assigned to area 1, the same or different user code must be entered within the
programmed number of minutes to prevent an ambush message from being sent to
the receiver. The second user code also must have authority to disarm area 1.
In addition, a zone activation with Alarm Action Message C also cancels the Early
Morning Ambush timer and stops an Ambush message from being sent to the receiver.
SeeReporttoTransmitsectioninZoneInformation.
The keypad does not display any indication that the ambush timer is running.
IndicationscanbeprovidedbyassigninganoutputnumbertoEntryOutandAmbush
OutinOutputOptions.EntryOutturnsononeminutebeforethetimerexpiresand
turnsoffatexpiration.AmbushOutturnsonatthetimers’expirationandturnsoff
when Sensor reset is performed.
18.10
AREA NO: -
Area Number
Enter the number of the area to program. After entering the area number, press
COMMANDtoentertheareaname.OnlyAreasystemsallowtheareanametobe
changed.
Note:WhenAll/PerimeterorHome/Sleep/Awayisselectedasthesystemtype,the
Area Number does not display.
18.10.1
All/Perimeter Programming
WhenAll/Perimeterisselectedasthesystemtype,programtheInteriorand
Perimeter areas as needed.
INT PERIM