DMP Electronics XR500 Home Security System User Manual


 
XR500 Series Canadian Programming Guide Digital Monitoring Products
39
STaTuS liST
Status List
15.1
STATUS LIST
Status List
This function allows you to select the zone alarms and troubles, and system monitor
troublesdisplayedatthekeypads.TheStatusListfunctionoperatesautomatically
when the keypad is not performing any other function.
ThekeypadstaysintheStatusListuntiltheuserarmsordisarmsorselectsamenu
option.StatusListalternateswiththeArmedStatusonkeypadaddressesselected
in the Menu Display - Armed Status section. You can choose to have Sys tem Monitor
troubles placed in the list, the differ ent zone types placed in the list, and at which
keypad addresses they dis play.
Toselectakeypad,enterthedevicenumber(keypadaddress)usingthedigitkeys
onthekeypad.Whenakeypadisselected,anasteriskappearsnexttothekeypad
address.Enterthenumberagaintodeselectthekeypad.PresstheCOMMANDkey
todisplaythenextsetofkeypads(9through16).RefertotheMultipleDisplays
section at the beginning of this document.
15.2
DISPLAY KEYPADS:
Display Keypads
Thisoptiondeneswhichkeypadaddressesdisplaythevariousstatusinformation.
Any combina tion of addresses can be en tered to display the status items that follow.
If you do not want a particular status item to dis play, do not enter any ad dresses.
15.3
SYSTEM TROUBLES:
System Monitor Troubles
Speciesthekeypadaddresses(1through16)whereanytroubleonaSystemMonitor
dis plays. The System Monitors include the following:
• ACPower
• BatteryPower
• ClosingCheck
• PanelBoxTamper
• PhoneLine1
• PhoneLine2 (requiresthe893ADualPhoneLineModule)
• WirelessReceiverTrouble
• WirelessJammingTroubleorAlarm
TheSystemMonitornameisplacedintheStatusListandthekeypadsteadytrouble
buzzer sounds. The buzzer remains on until any keypad top row Select key is
pressed. The name remains in the list until the condition is re stored. The buzzer
soundsat10:00amdailyuntilthesystemtroubleisclearedfromtheStatusList.
15.4
FIRE ZONES:
Fire Zones
Speciesthekeypadaddresses(1through16)whereallrezonealarmsandtroubles
display. The zone name displays and, if it is a trouble condition, the keypad steady
trouble buzzer sounds. The buzzer remains on until any top row Select key is
pressed and a user code is entered. If a trouble condition remains in the display, the
buzzersoundsat10:00amdailyuntilthetroubleisclearedfromtheStatusList.
WhenusingLCDKeypads,thepanelprovidesdistinctspeakertonesfromthekeypad
for Fire:
On - FirezonealarmandBellOutputorFireBellOutputisON.
Off - Alarm Silence