Communication
Congurethecommunicationoptionsforthepanel.Theinformationyouprogram
varies with the Communication Type you select.
3.2
ACCOUNT NO: 12345
Account Number
The Account Number is a 1 to 5 digit number used to identify which panel is sending
amessage.EntertheaccountnumbersenttotheSCS-1RReceiver.Messagesmay
besenttoacentralstationorviaPCLogReportstoaPC.Thedefaultis12345.
NET, CELL, 232 and DD - The range of valid account numbers for a panel is 1 to
65535.Foraccountsoffourdigitsorless,donotenterleadingzeros.
CID - Chooseanaccountnumberbetween1and9999.
3.3
XMIT DELAY: 30
Transmit Delay
Enterthenumberofseconds(15to45)thepanelwaitsbeforesendingburglary
zones(Night,Day,orExit)reportstothereceiver.Otherzonetypereportsare
sent immediately. Alarm bells and relay outputs are not delayed during this
period.ProgramBurglaryOutputsforpulsedorsteady,andsetAbortReportsto
YESifOpeningandClosingreportsarenotbeingsent.Enter0(zero)todisablethis
function. The default is 30.
If the area where the alarm occurred is disarmed during the Transmit Delay time,
onlyanAbortReport(S45)messageissenttothereceiver.Iftheareawhere
the alarm occurred is disarmed after the alarm message is sent to the receiver
but before the Bell Cutoff time expires even if the alarm was silenced, an Alarm
Cancelled(S49)messageissent.Otherwisethealarmissentattheendofthe
delay. The Alarm Cancelled report cannot be disabled.
Note: For Commercial Burglary Installations, the combined Transmit Delay
(Abort Window) and Entry Delay must not exceed one (1) minute.
3.4
PATH: -
Communication Path
Up to eight communication paths may be programmed. Each path is designated as
a primary or backup communication route. Path 1 is always Primary but other paths
may be programmed as additional primary or backup.
Each primary path establishes a new path group. A path group is made up of the
primary path and its subsequent backup paths. Typical communication takes place
on the primary path with backup paths being used only when the primary path fails
or when the backup path is programmed to duplicate messages. There is no option
tobackuppath8.
3.5
COMM TYPE: DD
Communication Type
Speciesthecommunicationmethodthepanelusesonthispathtoreportsystem
eventstoDMPSCS-1RReceiversornon-DMPreceivers.DefaultisDDforPath1,and
NONEforPath2-8.
NONE DD NET CID
NONE - Forlocalsystems.SelectingNONEendscommunicationprogramming.
DD - DigitalDialercommunicationstoaDMPSCS-1RReceiver.
NET - Network communication using the panel onboard network connection. The
DMPNetwork/Outputreportingformatistransmittedoveradatanetworktothe
SCS-1RReceiver.
CID - Thisoptionallowsthepaneltocommunicatetonon-DMPreceiversusingthe
Contact ID format.
CELL - ThisoptionallowscommunicationovertheGPRSnetworkusingdigital
cellulartechnologywiththe463GorCellComSeriesDigitalCellularCommunicator.
232 - This option sends serial data and can be used for radio backup or other
communicationoptions,andusestheon-boardserialport.
Select232whenusinga462NInterfaceCardorDB-9backupcommunicationsby
directlyconnectingtotheRS-232portonthepanel.Ifusingtheon-boardRS-232
port,settheXR500SeriesCanadianpanelJ23jumpertoRandbrieyresetthe
panelusingtheJ16jumpertoactivateRS-232operation.RefertotheXR500Series
CanadianInstallationGuide(LT-0681CAN).
CELL 232