7.4.3 PC Modem
YESallowsthepaneltoanswerthetelcolinkandconnectwithRemoteLinkthrough
thePCModemat2400baud.NOdisablesPCModemcommunication.
7.4.4 Manufacturer Authorization
Select YES to allow DMP Technical Support technicians to access the panel during
system service or troubleshooting. This authorization automatically expires within
one hour.
DMP remote service is provided on a read only basis: DMP technicians can look
at the system programming and make suggestions only. Alterations can only be
accomplished by installing company service personnel.
7.5 Allow Network Remote
This option displays only if the panel has network capability. YES allows remote
programming over the network. Changing this prompt does not change any other
network programming prompts. Default is YES.
7.5.1
NETWORK PROG
Network Programming Port
PORT: 2001
Entertheprogrammingportnumber.Theprogrammingportidentiestheportused
to communicate messages from the panel. The default Programming Port setting is
2001.
7.5.2 Encrypt Network Remote
YESencryptsdatasentovernetwork.DefaultisNO.
7.6 Allow Cellular Remote
YES allows remote programming using cellular connection. Default is YES.
7.6.1 First GPRS APN
EntertherstAPN(AccessPointName).Thisallowsanaccesspointforcellular
communication and is used to connect to a DNS network. The APN may contain two
linesof16characterstoequal32characters.DefaultissettoSECURECOM400.
Second GPRS APN
EnterthesecondAPN(AccessPointName).Thisworksasabackupincasetherst
APNfails.TheAPNmaycontaintwolinesof16characterstoequal32character
DefaultissettoSECURECOM400.
7.6.2 Encrypt Cellular Remote
YESencryptsdatasentoveracellularconnection.DefaultisNO.
7.7 Allow RS-232 Remote
YESallowsremoteprogrammingovertheon-boardRS-232port.DefaultisYES.
7.8 Entré Connection
This option displays only if the panel has network capability. Select NET to allow
adedicatednetworkconnectionwithEntré.OptionsareNONEorNET.Defaultis
NONE.
7.8.1 Entré Incoming TCP Port
ThisoptiondisplaysonlyifNETischosenfortheEntréconnection.Enterthe
programmingportnumberfortheincomingEntréconnection.Theprogrammingport
identiestheportusedtocommunicatemessagestoandfromtheEntrésoftware.
This port cannot be the same port as programmed in Network Programming Port.
The default Programming Port setting is 2011.
7.8.2 Entré IP Address
ThisoptiondisplaysonlyifNETischosenfortheEntréconnection.EntertheEntré
IPaddresswherethepanelsendsnetworkmessages.TheEntréIPAddressmustbe
unique and cannot be duplicated on the network. Enter all 12 digits and leave out
theperiods.Forexample,enterIPaddress192.168.0.250as192168000250.The
periods display automatically. Default is 0.0.0.0
7.8.3 Entré Outbound TCP Port
ThisoptiondisplaysonlyifNETischosenfortheEntréconnection.Enterthe
programmingportnumberfortheoutboundEntréconnection.Theprogrammingport
identiestheportusedtocommunicatemessagestotheEntrésoftware.Defaultis
2001.
SECURECOM400
-
FIRST GPRS APN:
SECURECOM400
-
SECOND GPRS APN:
ENCRYPT NETWORK
REMOTE? NO YES
ALLOW CELL
REMOTE? NO YES
ENCRYPT CELL
REMOTE? NO YES
ALLOW 232
REMOTE? NO YES
ENTRE
CONNECTION: NONE
ENTRE INCOMING
TCP PORT: 2011
000.000.000.000
ENTRE IP
ENTRE OUTBOUND
TCP PORT: 2001
AUTH? NO YES
ALLOW NETWORK
REMOTE? NO YES
PC MODEM NO YES
MANUFACTURER