XR500 Series Canadian Programming Guide Digital Monitoring Products
23
remoTe oPTionS
7.4.3 PC Modem
YESallowsthepaneltoanswerthetelcolinkandconnectwithRemoteLinkthrough
thePCModemat2400baud.NOdisablesPCModemcommunication.
7.4.4 Manufacturer Authorization
Select YES to allow DMP Technical Support technicians to access the panel during
system service or troubleshooting. This authorization automatically expires within
one hour.
DMP remote service is provided on a read only basis: DMP technicians can look
at the system programming and make suggestions only. Alterations can only be
accomplished by installing company service personnel.
7.5 Allow Network Remote
This option displays only if the panel has network capability. YES allows remote
programming over the network. Changing this prompt does not change any other
network programming prompts. Default is YES.
7.5.1
NETWORK PROG
Network Programming Port
PORT: 2001
Entertheprogrammingportnumber.Theprogrammingportidentiestheportused
to communicate messages from the panel. The default Programming Port setting is
2001.
7.5.2 Encrypt Network Remote
YESencryptsdatasentovernetwork.DefaultisNO.
7.6 Allow Cellular Remote
YES allows remote programming using cellular connection. Default is YES.
7.6.1 First GPRS APN
EntertherstAPN(AccessPointName).Thisallowsanaccesspointforcellular
communication and is used to connect to a DNS network. The APN may contain two
linesof16characterstoequal32characters.DefaultissettoSECURECOM400.
Second GPRS APN
EnterthesecondAPN(AccessPointName).Thisworksasabackupincasetherst
APNfails.TheAPNmaycontaintwolinesof16characterstoequal32character
DefaultissettoSECURECOM400.
7.6.2 Encrypt Cellular Remote
YESencryptsdatasentoveracellularconnection.DefaultisNO.
7.7 Allow RS-232 Remote
YESallowsremoteprogrammingovertheon-boardRS-232port.DefaultisYES.
7.8 Entré Connection
This option displays only if the panel has network capability. Select NET to allow
adedicatednetworkconnectionwithEntré.OptionsareNONEorNET.Defaultis
NONE.
7.8.1 Entré Incoming TCP Port
ThisoptiondisplaysonlyifNETischosenfortheEntréconnection.Enterthe
programmingportnumberfortheincomingEntréconnection.Theprogrammingport
identiestheportusedtocommunicatemessagestoandfromtheEntrésoftware.
This port cannot be the same port as programmed in Network Programming Port.
The default Programming Port setting is 2011.
7.8.2 Entré IP Address
ThisoptiondisplaysonlyifNETischosenfortheEntréconnection.EntertheEntré
IPaddresswherethepanelsendsnetworkmessages.TheEntréIPAddressmustbe
unique and cannot be duplicated on the network. Enter all 12 digits and leave out
theperiods.Forexample,enterIPaddress192.168.0.250as192168000250.The
periods display automatically. Default is 0.0.0.0
7.8.3 Entré Outbound TCP Port
ThisoptiondisplaysonlyifNETischosenfortheEntréconnection.Enterthe
programmingportnumberfortheoutboundEntréconnection.Theprogrammingport
identiestheportusedtocommunicatemessagestotheEntrésoftware.Defaultis
2001.
SECURECOM400
-
FIRST GPRS APN:
SECURECOM400
-
SECOND GPRS APN:
ENCRYPT NETWORK
REMOTE? NO YES
ALLOW CELL
REMOTE? NO YES
ENCRYPT CELL
REMOTE? NO YES
ALLOW 232
REMOTE? NO YES
ENTRE
CONNECTION: NONE
ENTRE INCOMING
TCP PORT: 2011
000.000.000.000
ENTRE IP
ENTRE OUTBOUND
TCP PORT: 2001
AUTH? NO YES
ALLOW NETWORK
REMOTE? NO YES
PC MODEM NO YES
MANUFACTURER