DMP Electronics XR500 Home Security System User Manual


 
Digital Monitoring Products XR500 Series Canadian Programming Guide
46
area informaTion
18.10.2
INT BDRM PERIM
Home/Sleep/Away Programming
WhenHome/Sleep/Awayisselectedasthesystemtype,programtheInterior,
Bedroom, and Perimeter areas as needed.
18.11
* UNUSED *
Area Name
The area name can be up to 32 alphanumeric characters. To add an area name to the
system, press any Select key and then enter up to 32 characters for the new area name.
PressCOMMANDtocontinue.Forinstructionsonenteringalphanumericcharacterssee
section1.7EnteringAlphaCharacters.Inactiveareasaremarked*UNUSED*.Only
systems programmed for Area arming have the option available to change the area name.
To mark an active area unused, press any top row Select key to delete the old name,
thenpresstheCOMMANDkey.Theprogrammerautomaticallyprogramsthename
as*UNUSED*.IfyouhavealreadyclearedAreaInformationduringInitialization,all
areasaremarked*UNUSED*.SeeInitializationsection.
Home/Sleep/AwaywithGuestsystemsdisplaytheareaname,butthenamescannot
be changed. The following are the display names that appear on the keypad:
Area Display Area Display Area Display
1 Perimeter 4 Guest1Perimeter 7 Guest2Perimeter
2 Interior 5 Guest1Interior 8 Guest2Interior
3 Bedrooms 6 Guest1Bedrooms 9 Guest2Bedrooms
18.12
ACCOUNT NO: 12345
Account Number
Enter the account number to be sent to the receiver for this area. Choose an account
number compatible with the Communication Type selected in Communications. The
default Account Number is the one previously entered in Communications. This
account number is used when sending area messages and events to the central station
.
See the Area Account Number Messages in the Appendix.
18.13
AUTO ARM NO YES
Automatic Arming
Select YES to allow this area to arm automatically according to permanent, temporary,
or extended schedules. If no schedules are programmed, the area auto arms every hour.
If closing check is selected as YES, the automatic arming function does not take
place until the expiration of a ten minute Closing Check delay. See Closing Check.
If the area has been disarmed outside of any permanent or temporary schedule, the
closing check sequence occurs one hour after the area is disarmed.
At arming, bad zones are handled according to the option selected in section Bad
Zones.Ifaclosingreportissent,theusernumberisindicatedasSCHontheSCS-1R
Receiver.NOdisablesautomaticarmingforthisarea.
18.14
BAD ZONES: BYP
Bad Zones
At the time of automatic arming, some zones in the area may not be in a normal
condition. This option allows you to program the panel response to these bad zones.
ThisoptiondoesnotdisplayifAUTOARMisNO.
BYP FORC REF
BYP - All bad zones are bypassed. A report of the bypass is sent to the receiver if
Bypass Reports is YES. The report indicates SCH as the user number.
FORC - Allbadzonesareforcearmed.Zonesforcearmedinabadconditionare
capable of restoring and reporting an alarm if tripped. A forced zone report is
transmitted if Bypass Reports is YES. The report indicates SCH as the user number.
REF - The automatic arming is refused and no arming takes place. A No Closing
report is sent to the receiver regardless of the Closing Check selection.
18.15
AUTO DIS NO YES
Automatic Disarming
NOdisablesautomaticdisarmingbyscheduleforthisarea.WhenYESisselected,
the area automatically disarms according to permanent or temporary schedules. If
an opening report is sent to the receiver, the user number is indicated as SCH.