ouTPuT oPTionS
11.6
PANIC ALM OUT: 0
Panic Alarm Output
Enter the output number to turn on when any Panic type zone is placed in an alarm
condition. The output is turned off after all Panic zones are restored from an alarm
conditionandaSensorResetisperformed.Enter0(zero)todisable.
Wireless Outputs
• ThePanicAlarmiscompatiblewiththeModel1118WirelessRemoteIndicator
LightandtheModel1116WirelessRelayOutputconnectedtoaModel572
IndicatorLED.
• WhenaPanicAlarmoccurs,theLEDturnsonsteadyforveminutesandthen
turns off.
• WhenaPanicTestisinitiatedfromthekeypad,theLEDashesquicklyforve
minutes.
• ForaPanicAlarm,afastresponsewirelessoutputnumberisrecommended.
11.7
AMBUSH OUT: 0
Ambush Output
Enter the output number to turn on when an Ambush code is entered at a keypad.
TheoutputisturnedoffusingtheSensorResetoption.Enter0(zero)todisable.
11.8
ENTRY OUT: 0
Entry Output
Enter the output number to turn on at the start of the entry delay time. The output
turnsoffwhentheareaisdisarmedortheentrydelaytimeexpires.Enter0(zero)
to disable.
11.9
EXIT OUT: 0
Exit Output
Enter the output number to turn on when an exit delay time starts in any area of
the system. The output turns off when the area arms or when the arming has been
stopped.Enter0(zero)todisable.
11.10
READY OUT: 0
Ready Output
Enter the output number to turn on when all disarmed burglary zones are in a
normal state. The output is turned off when any disarmed burglary type zone is in
abadstate.Enter0(zero)todisable.ThisoutputisnotcompatiblewithCutoff
Outputs.
11.11
PH TRBL OUT: 0
Telephone Trouble Output
Enter the output number to turn on when the phone line monitor on the panel phone
lineislost.Enter0(zero)todisablethisoutput.
11.12
LATE CLS OUT: 0
Late To Close Output
Enter the output number to turn on at the expiration of a Closing schedule. The
outputactivatessimultaneouslywiththeCLOSINGTIME!keypaddisplay.Theoutput
is turned off when the area is armed, the Closing is extended, or the schedule is
changed.Enter0(zero)todisablethisoutput.
11.13
DVC FAIL OUT: 0
Device Fail Output
Enter the output number to turn on when an addressed device fails to respond to
polling from the panel. A Missing Device report is sent to the receiver. The output
is turned off when the device responds to polling or is removed from programming in
thesystem.Enter0(zero)todisablethisoutputandLX-Bus™devicefailreporting
to the receiver. If any addressed device is unsupervised, this output cannot be used.
11.14
SNSR RST OUT: 0
Sensor Reset Output
Enter the output number to turn on when a Sensor Reset is performed at a keypad.
The output turns off automatically 5 seconds later. This function can be used to
reset smoke detectors that are operated by an external power supply through a
Model716OutputExpanderModule.Enter0(zero)todisablethisoutput.