SySTem rePorTS
System Reports
8.1
SYSTEM REPORTS
System Reports
Selectspecicsystemreportsthepanelsendstothereceiver.
8.2
ABORT NO YES
Abort Report
YES allows the panel to send an alarm abort report to the receiver any time an area
is disarmed during Transmit Delay before an alarm report is sent and the Bell Cutoff
Time has not expired. After disarming an area, if any other area remains armed and
haszone(s)inalarm,thealarmabortreportisnotsent.
IfthecommunicationtypeissettoDD,aWarning:AlarmBellSilencedreportisalso
sent if the alarm bell is silenced.
Note: Abort Reports are not sent for Fire, Fire Verify, or Supervisory type zones.
8.3
RESTORAL: YES
Restoral Reports
This option allows you to control when and if a zone restoral report is sent to the
central station receiver. Press any Select key to display the following options:
NO YES DISARM
NO -Disablesthezonerestoralreportoption.Zonescontinuetooperatenormally
but do not send restoral reports to the receiver.
YES -Enablesthezonerestoralreportoption.Zonerestoralsaresentwhenevera
zone restores from a trouble or alarm condition.
DISARM -Causesthepaneltosendrestoralreportsforanon-24-hourzonewhenever
azonethathasrestoredfromatroubleoralarmconditionisdisarmed.All24-hour
zones send restoral reports as they restore.
8.4
BYPASS NO YES
Bypass Reports
YES allows the panel to send all zone bypasses, resets, and force arm reports to the
receiver. The bypass report includes the zone number, zone name, and the user
name and number of the individual operating the system. Reports are only sent if
O/CUserinCommunicationsissetYESforReceiver1orReceiver2.
8.5
SCHD CHG NO YES
Schedule Change Reports
YES allows the panel to send all schedule changes to the receiver. The report
includes the day, opening time, closing time, extend schedule time, and the user
name and number of the individual making the change. Schedule changes made
throughRemoteLink™arenotsenttotheprinterorDisplayEvents.
8.6
CODE CHG NO YES
Code Change Reports
YES allows the panel to send all code additions, changes, and deletions to the
receiver. The code change report includes the user name and number added or
deleted and the user name and number of the individual making the change. Code
changesmadethroughRemoteLink™arenotsenttotheprinterorDisplayEvents.
ReportsareonlysentifO/CUserinCommunicationsissetYESforReceiver1or
Receiver 2. The default setting is YES.
8.7
ACCESS KEYPADS:
Access Keypads
Selectthekeypadaddresses(1through16)thatsenddooraccessreportstothe
receiver. Enter the keypad number using the digit keys. An asterisk next to the
numberindicatesthatthekeypadisselected.PressCOMMANDtodisplaythenext
set of keypads.
Areportissentwitheachdooraccessmadefromtheselectedkeypads.Keypadsat
addresses not selected still operate the door relay but do not send access reports.
The report includes the user number, user name, keypad address, and device name.