DMP Electronics XR500 Home Security System User Manual


 
Digital Monitoring Products XR500 Series Canadian Programming Guide
70
aPPendiX
Keypad Bus Zone
Information
Type Area Fire
Bell
Disarmed
Open
Disarmed
Short
Armed
Open
Armed
Short
Swinger
Prewarn
Entry Delay
Retard Delay
Presignal
Fast Response
Cross Zone
Priority
Follow Area
Real-Time Rprts
Door Number
Style
Assign Disarm condition of
NT, DY, EX, A1, and A2 only
Assign Prewarn and Entry
Delay for EX only
Assign Retard and Presignal
for FI, SV, A1, and A2 only
Zone Type Defaults
--
DY
FI
EM
A1
FV
NT
EX
PN
SV
A2
AR
INT
PERIM
BDRM
or
1
to
32
Output *
Message
Output *
Action
Message
Output *
Action
Message
Output *
Action
Message
Output *
Action
A
T
L
-
D
S
C
S
P
M
F
A
T
L
-
D
S
C
S
P
M
F
A
T
L
-
D
S
C
S
P
M
F
A
T
L
-
D
S
C
S
P
M
F
N
or
Y
1
to
16
1
or
4
N
or
Y
1
to
16
N
or
Y
N
or
Y
N
or
Y
0
to
16
N
or
Y
0
to
16
TGL
ARM
DIS
STEP
MNT
Night NT - 0 S - 0 S A 0 S A 0 S Y N N N 0 N 0
Day DY T 0 S T 0 S A 0 S A 0 S Y N N N 0 N 0
Exit EX - 0 S - 0 S A 0 S A 0 S Y
1-16
1 N N N N 0
Fire FI 0 T 0 S A 0 S N N + N N N
Panic PN T 0 S A 0 S N N N N
Emergency EM T 0 S A 0 S N N N N
Supervisory SV 0 T 0 S A 0 S N N + N N N
Auxiliary 1 A1 T 0 S A 0 S T 0 S A 0 S N N + N N N 0 N 0
Auxiliary 2 A2 T 0 S A 0 S T 0 S A 0 S N N + N N N 0 N 0
Fire Verify FV 0 T 0 S A 0 S N N N
Arming AR TGL
*OutputOptions:1to6,450to474,480to499,500to999,D1toD16,G1toG20. + =SetretardtoYESbeforeselectingpresignal. =Zonefunctionsnotavailable.
23.12.1
Keypad Bus Zone Type Defaults
These are complete spellings of the abbreviations used for the zone types, such as Night and Exit.
Type -Thesearetheabbreviationsusedforthezonetypes,suchasNTandEX.
Area-ForanAreaorHome/Sleep/AwaywithGuestsystemthisis1to32.ForanAll/PerimeterorHome/
Sleep/Awaysystem,thisistheInterior,Bedroom,orPerimeter.SelecttheareaforNT,DY,EX,A1,A2,and
AR types.
Fire Bell Out -OnlyavailableforFI,FV,andSVzones.Useanyoutputzonenumberlisted.
Message -A=alarmreport,T=troublereport,L=local,noreport,(dash)=noreport,D=doorpropped
(WhenSVzoneisconnectedto303Silence/ResetSwitch),S=sensorreset/alarmsilence,
C=earlymorningambushcancel.
Output -Theseare1to6on-boardand500to999off-boardrelayoutputs,450to474and480to499
wirelessoutputs,D1toD16,andG1toG20.
Action -Thisselectstheactionoftheoutput:S=steady,P=pulse,M=momentary,andF=follow
Swinger -Thezonecanbeautomaticallyshuntedafteraprogrammednumberoftrips.
Prewarn -Thisselectsthekeypadaddressthatsoundstheentryprewarnforthiszone.
Entry Delay-Thisistheentrydelaytimerselectedasthedefaultforthiszone.
Retard Delay-Providesaprogrammedretardtimebeforeanalarminitiatesfromashortedzone.When
used on an arming zone, the retard delay occurs when the zone is shorted before the armed state has
changed. If the arming zone has Maintain as the Style, the retard delay also occurs when the zone returns
to a normal state.
Presignal -Providesakeypadtoneforzonesinretarddelay.RetardmustbeYESbeforePresignalcanbe
selected.
Fast Response-Providesa167mszoneresponseinsteadofthenormal500msresponse.
Cross Zone-Providescrosszoningwithanyofthe574zones.
Priority -Requiresthiszonetobeinanormalconditionbeforetheareacanbearmed.
Style - The abbreviations for arming zone style:
TGL=Toggle,ARM=Armonly,DIS=Disarmonly,STEP=Wirelessarming,MNT=Maintain