DMP Electronics XR500 Home Security System User Manual


 
Digital Monitoring Products XR500 Series Canadian Programming Guide
66
aPPendiX
If ENHANCED ZONE TEST is selected as YES:
A Verify message is sent at the time the zone trip occurs instead of at the end of the
WalkTest.ForFI,FVorSVzonetypes,theVerifymessageissentattheinitialtrip.
For all other zone types, the Verify message is sent when the zone restores. This
allows the Central Station to count the number of devices per zone.
END - SelectENDtostoptheWalkTest.WhentheWalkTestendsora20-minute
time-outexpires,analSensorResetoccurs.TheSystemTestEndmessageis
sent to the receiver along with Verify and Fail messages for each zone under test.
Faulted zones then display on the keypad.
CKIN:XXX/ZZZ END
Trip Counter For DMP Wireless Check-in Test (WLS)
Displays the number of wireless zones that automatically communicate a supervision
check-inmessage.
• Thenumberofzonesthatcheckin.(XXXintheexample).
• Thetotalnumberofwirelesszonesprogrammedforsupervisionthatshould
checkin.(ZZZintheexample).
END -SelectENDtostoptheWirelessCheck-inTest.Whenthetestendsor
a20-minutetime-outexpires,normalwirelesszoneprocessingreturns.If
alltransmitterscheck-in,bothnumbersmatchwithinthree(3)minutes.Ifa
transmitterhasmultiplezones(1101,1114,etc.),allzonesareincludedinthe
counts. Failed wireless zones display on the keypad.
TEST END WARNING
Test End Warning
Whenveminutesremainonthe20minuteWalkTesttimer,thekeypaddisplays
TESTENDWARNING.Ifnoadditionaltestzonetripsoccur,thetestendsandanal
Sensor Reset automatically occurs. The System Test End message is sent to the
receiveralongwithVerifyandFailmessagesforeachzoneunderWalktest.Faulted
zones then display on the keypad.
Failed Zones Display
ZONE: 10 -FAIL
Foreachzonethatdidnottrip(failed)atleastonceduringtheWalkTest,all
keypads with matching Area Display programming display the zone name and number
andbuzzforonesecond.Anyselected(*FI*PN*SV)24-hourzonethatisfaultedat
theendoftheWalkTestdisplaysatroubleconditionforthatzoneregardlessofthe
message programmed for the open or short condition of the zone and a zone trouble
issenttothereceiver.PresstheCOMMANDkeytodisplaythenextfailedzone.
Note:FortheWirelessCheck-inTest,failedwirelesszonesdisplayonlyonthe
keypad.ZoneVerify/Failreportsarenotsenttothecentralstationreceiverforthe
wirelesscheck-intest.
Local Printer for Walk Test
WhentheWalkTestiscompleted,aVerifyorFailmessageforeachzonetestedprintstothelocalprinter.
TheWalkTestmessagesprintingisenabledthroughPrinterReportsprogramming.
Note:IfENHANCEDZONETESTisselectedasYES,theVerifymessagesareprintedatthetimethezone
trip occurs and not printed at the test end.
23.5 Keypad Speaker Operation
WhenusingLCDKeypads,thepanelprovidesdistinctspeakertonesfromthekeypadforFire,Burglary,
ZoneMonitor,andPrewarnevents.Thelistbelowdetailstheconditionsunderwhichthespeakeristurned
on and off for each event.
Fire On-FirezonealarmandBellOutputorFireBellOutputisON.
Off -AlarmSilence.
Burglary On -BurglaryzonealarmandBellOutputorBurglaryBellOutputisON.
Off-AlarmSilence.
Zone Monitor On-Onetimeonlywhenamonitoredzoneistripped.
Off-Afteronetone.
Prewarn On-DuringEntryDelay.
Off-WhenEntryDelayexpires.
SOUTH LOBBY