Mitsubishi Electronics C6 Home Safety Product User Manual


 
Appendix 3. PLC Development Environment using GPPQ
3.6 PLC-Related Data Development Procedure
- 458 -
(3) Commercially Available Software QnA Conversion Setting
The screen is selected from the menu using the following CNVQ basic operation.
1F11 ( HOME CLR )
Mode
Mode
selection
menu screen
Commercially
available
software
QnA
Commercially
available
software QnA
conversion
setting screen
The conversion source/destination directory path and conversion file name, etc., are set on the
following screen. Refer to the Operating Manual for details.
Other --> QnA Convert C:M600\TEST\SETUPM1 <Ins> F11:Mode
Conversion Destination File
Drive/Path[C:\GPPQ\USR
Conversion Source File
Drive/Path[C:\CNVQ\USR\M600\TEST
# Conv SourceFile DestFile Data # FileType ConvType Another
000 [ ] [M1TEST ] [M600\TEST\M1TEST ] [ 1] <Text> < List > [ ]
001 [ ] [ ] [ ] [ ] < > < > [ ]
002 [ ] [ ] [ ] [ ] < > < > [ ]
003 [ ] [ ] [ ] [ ] < > < > [ ]
004 [ ] [ ] [ ] [ ] < > < > [ ]
005 [ ] [ ] [ ] [ ] < > < > [ ]
006 [ ] [ ] [ ] [ ] < > < > [ ]
007 [ ] [ ] [ ] [ ] < > < > [ ]
008 [ ] [ ] [ ] [ ] < > < > [ ]
009 [ ] [ ] [ ] [ ] < > < > [ ]
010 [ ] [ ] [ ] [ ] < > < > [ ]
PgUp : Prev Page PgDn : Next Page Ctrl+P :Drive/Path Enter : Decide
(4) Conversion Execution
The screen is selected from the menu using the following CNVQ basic operation.
Project
menu
window
Conversion
execution
confirmation
screen
1Alt ( GRPH )
4
Menu
Commercially
available
software QnA
conversion
setting screen
Project
Execution
The conversion status appears at the bottom of the screen. If "There were n conversion errors"
appears when the conversion is finished, the conversion error edit screen is displayed from the
menu using the following CNVQ basic operation, and the error contents confirmed.
Conversion
error menu
window
2
Alt ( GRPH )
1
Menu
Commercially
available
software QnA
conversion
setting screen
Conversion
error
Edit
Conversion
error edit
window