8. Function Commands
*, *P
- 171 -
Execution conditions
The execution conditions for *, *P are as shown below.
Multiplication command OFF
*
ON
Executed per scan
Executed per scan
*P
Program example
(1) Program to multiply the D0 data and BIN 5678 when X5 turns ON, and output the results to D3,
4.
Coding
No. of
steps
Com-
mand
Device
10 LD X5
11 * D0 K5678 D3
*
K5678D0
D3
X5
10
15
(2) Program to multiple the D0 BIN data and D10 BIN data, and output the results to D20.
Coding
No. of
steps
Com-
mand
Device
10 LD M0
11 * D0 D10 D20
*
D10
D0 D20
M0
(ON)
10
15