FX3S/FX3G/FX3GC/FX3U/FX3UC Series
Programming Manual - Basic & Applied Instruction Edition
A Programming Tool Applicability and Version Upgrade History
A-3 Version Upgrade History
Appendix A-3-2 Version check
The PLC version can be verified by monitoring the special data register D8001 or D8101 and checking the last three
digits. Or for the FX
3U and FX3UC PLCs, the PLC version can be verified in "PLC Status" within the display module.
For the operating procedure of the display module,
refer to the Hardware Edition Manual of the PLC to be checked.
Appendix A-3-3 Version upgrade history [FX3S]
Appendix A-3-4 Version upgrade history [FX3G]
For the manufacturer’ serial number check method, refer to Appendix A-3-1.
Version
Manufacturer’s
serial number
Contents of version upgrade
Ver. 1.00
133****
(March, 2013)
First product
Ver. 1.10
13X****
(October, 2013)
•FX3S-30M/E-2AD (First product)
Supports connection of the following expansion board:
-FX3G-4EX-BD, FX3G-2EYT-BD
Version
Manufacturer’s
serial number
Contents of version upgrade
Ver. 1.00 86**** (June, 2008) First product
Ver. 1.10
8X****
(October, 2008)
Supports following 15 instructions:
FLT (FNC 49), VRRD (FNC 85), VRSC (FNC 86), ECMP (FNC110), EMOV (FNC112),
EADD (FNC120), ESUB (FNC121), EMUL (FNC122), EDIV (FNC123),
ESQR (FNC127), INT (FNC129), IVCK (FNC270), IVDR (FNC271), IVRD (FNC272),
IVWR (FNC273)
Supports connection of FX3G-8AV-BD, FX3G-2AD-BD, and FX3G-1DA-BD.
Supports connection of display module (FX3G-5DM).
Supports the floating point operation function.
Supports the inverter communication function.
Supports the pulse width/pulse period measurement function.
Ver. 1.20
96****
(June, 2009)
Supports connection of following analog special adapters:
-FX3U-3A-ADP
Supports the hardware error function of FX3U-4DA-ADP.
Ver. 1.30
9Z****
(December, 2009)
Supports the following instructions:
ADPRW(FNC276)
Ver. 1.40
111****
(January, 2011)
Supports the following instructions:
IVMC(FNC275)
Ver. 2.00
124****
(April, 2012)
Supports the following functions of the FX3U-16CCL-M:
- Network parameter
- Accessing the other station from CC-Link
- Remote device station initialization procedure registration
- CC-Link diagnostics
Special parameter error (M8489 and D8489) is added.
Ver. 2.10 134**** (April, 2013) Supports the IP address change function of Ethernet adapter.
Ver. 2.20
13X****
(October, 2013)
Supports connection of the following expansion board:
-FX3G-4EX-BD, FX3G-2EYT-BD
D8001/D8101
PLC type and
version
2 4 1 0 0
Version information (Example: Ver. 1.00)
PLC type (Example: 24 = FX
3U/FX3UC PLCs)