FX3S/FX3G/FX3GC/FX3U/FX3UC Series
Programming Manual - Basic & Applied Instruction Edition
2 Overview (Sequence Program)
2.7 Types and Setting of Parameters
1
Introduction
2
Overview
3
Instruction
List
4
Devices
in Detail
5
Specified the
Device &
Constant
6
Before
Programming
7
Basic
Instruction
8
FNC00-FNC09
Program Flow
9
FNC10-FNC19
Move & Compare
10
FNC20-FNC29
Arith. & Logic
Operation
*1. The setting range is from 10 to 100,000 Hz in FX3G/FX3GC/FX3U/FX3UC PLCs.
The setting range is from 10 to 200,000 Hz in FX
3U PLC when the pulse output destination is the high-speed
output special adapter.
*2. The creep speed should satisfy the relationship "Bias speed Creep speed Maximum speed".
*3. An interrupt input set here cannot be used jointly with a high-speed counter, input interrupt, pulse catch input,
input in SPD (FNC 67) instruction, or interrupt input in DVIT (FNC151) instruction.
*4. This area can be set only in FX
3U/FX3UC PLCs.
*5. Y002 is not set in FX
3G PLC (14-point and 24-point type) and FX3GC PLC.
*6. Note that this item can only be set if two high-speed output special adapters are connected to the FX
3U PLC.
Set item Contents of setting Set range
Bias Speed [Hz]
Set the bias speed for each set of output pulses.
Initial value: 0
1/10 or less of the
maximum speed
Max. Speed [Hz]
Set the maximum speed for each set of output pulses.
Initial value: 100,000
*1
Creep Speed [Hz]
Set the creep speed in DSZR (FNC150) instruction for each set of output pulses.
Initial value: 1000
10 to 32767
*2
Zero Return Speed [Hz]
Set the zero point return speed in DSZR (FNC150) instruction for each set of
output pulses.
Initial value: 50000
*1
Acceleration Time [ms]
Set the acceleration time for each set of output pulses.
Initial value: 100
50 to 5000
Deceleration Time [ms]
Set the deceleration time for each set of output pulses.
Initial value: 100
50 to 5000
Interruption Input of DVIT
Instruction
*4
Set the interrupt input
*3
for DVIT (FNC151) instruction for each set of output
pulses. Specify a user interrupt command device (M) for a pulse output
destination device not used in DVIT instruction.
Initial setting: Setting range:
Pulse output destination Y000: X000 X000 to X007, M8460
Pulse output destination Y001: X001 X000 to X007, M8461
Pulse output destination Y002: X002 X000 to X007, M8462
Pulse output destination Y003
*6
: X003 X000 to X007, M8463
As shown on the left
Y0 Setting for Fixed pulse output destination terminal Y000.
Y1 Setting for Fixed pulse output destination terminal Y001.
Y2
*5
Setting for Fixed pulse output destination terminal Y002.
Y3
*6
Setting for Fixed pulse output destination terminal Y003.
Individual Setting
This button displays "Positioning instruction settings" dialog box for setting the
table used in TBL (FNC152) instruction.
For the setting procedure, refer to the next page.