FX3S/FX3G/FX3GC/FX3U/FX3UC Series
Programming Manual - Basic & Applied Instruction Edition
27 Data Operation 3 – FNC210 to FNC219
27.3 FNC212 – POP / Shift Last Data Read [FILO Control]
Subtract “1” from the value of the pointer data .
Related device
For the zero flag use method, refer to Subsection 6.5.2.
Related instructions
Cautions
When this instruction is programmed in the continuous operation type, the instruction is executed in every operation
cycle. As a result, an expected operation may not be achieved.
Usually, program this instruction in the “pulse operation type”, or let this instruction be executed by a “pulsed
command contact”.
When the current value of the pointer is “0”, the zero flag M8020 turns ON and the instruction is not
executed.
Check in advance using a comparison instruction whether the current value of satisfies “1 n-1”,
and then execute this instruction.
When the current value of the pointer is “1”, “0” is written to and the zero flag M8020 turns ON.
Error
An operation error is caused in the following cases; The error flag M8067 turns ON, and the error code is stored in
D8067.
When is larger than “n-1” (error code: K6706)
When is smaller than “0” (error code: K6706)
Device Name Description
M8020 Zero flag
Turns ON when the instruction is executed while the pointer is “0”.
Instruction Description
SFWR (FNC 38) Shift write [for FIFO/FILO control]
SFRD (FNC 39) Shift read [for FIFO control]
S
Data area
Pointer
S
+n-2
S
+n-1
S
+6
S
+5
S
+3
S
+2
S
+1
S
No data area
Pointer
S
+n-2
S
+n-1
S
+6
S
+5
S
+3
S
+2
S
+1
S
D
S
+4
In the case of K4
K4
K3
S
+4
S
S
S
S
S
S
S
S